Các lỗi thường gặp

Code :
  • Code: 621
  • Description: Communication error – FCI I2C
    The engine board detected an unknown device on the I2C I/F bus (internal bus on the engine control board). The engine board detected an I2C I/F bus error. The number of devices connected to the I2C bus exceeded 12.
  • Causes: • Engine board defectiveI I2C
  • Code: 634
  • Description: Key/card counter device error 3
    The backup battery of the counter device RAM is low.
  • Causes: • Replace the RAM backup battery.
  • Code: 635
  • Description: Key/card counter device error 4
    After installation of the device a message alerts user to a battery voltage abnormal error.
  • Causes: • Device control board defective • Device control board backup battery defective
  • Code: 650
  • Description: Communication error – GAVD I2C
    The engine board detected an unknown device on the I2C I/F bus (internal bus on the engine control board). The engine board detected an I2C I/F bus error. The number of devices connected to the I2C bus exceeded 12.
  • Causes: • Engine board defective
  • Code: 651
  • Description: Communication error – FCI I2C
    The engine board detected an unknown device on the I2C I/F bus (internal bus on the engine control board). The engine board detected an I2C I/F bus error. The number of devices connected to the I2C bus exceeded 12.
  • Causes: • Engine board defectiveI I2C
  • Code: 669
  • Description: NVRAM Error
    The NVRAM was not connected at power on, or read/write operations on the NVRAM failed.
  • Causes: • NVRAM connected improperly • NVRAM missing
  • Code: 670
  • Description: Engine startup error
    The BCU failed to respond with the prescribed time when the machine was turned on.
  • Causes: • Connections between BCU and controller board are loose, disconnected, or damaged • Replace the BCU • Replace the controller board
  • Code: 672
  • Description: Controller startup error
    After power on, the line between the controller and the operation panel did not open for normal operation. After normal startup, communication with the controller stopped.
  • Causes: • Controller stalled • Controller installed incorrectly • Controller board defective • Operation panel harness disconnected or defective