Các lỗi thường gặp

Code :
  • Code: 900
  • Description: Electrical total counter error
    The total counter contains something that is not a number.
  • Causes: • NVRAM incorrect type • NVRAM defective • NVRAM data scrambled • Unexpected error from external source
  • Code: 920
  • Description: Printer error 1
    An internal application error was detected and operation cannot continue.
  • Causes: • Software defective; turn the machine off/on, or change the controller firmware • Insufficient memory
  • Code: 990
  • Description: Software error 1
    The software performs an unexpected function and the program cannot continue.
  • Causes: Software defective, re-boot
  • Code: 991
  • Description: Software error 2
    The software performs an unexpected function. However, unlike SC990, recovery processing allows the program to continue.
  • Causes: Software defective, re-boot
  • Code: 995
  • Description: Model information error
    The CPM information sent from the controller to the engine immediately after power on did not match the DIP SW settings.
  • Causes: • Engine firmware not installed correctly