Các lỗi thường gặp

Code :
  • Code: 795-45
  • Description: Cover Horizontal Registration Sensor: Small (S71) PB (D391) The value for the adjustment of the cover registration sensor was higher than or lower than the target range: 3.2V to 3.5V
  • Causes: • Cover horizontal registration sensor: small (S71) defective • D/A converter defective • A/D converter defective
  • Remedy:
  • Code: 795-46
  • Description: Cover Horizontal Registration Sensor: Large (S72) PB (D391) The value for the adjustment of the cover horizontal registration sensor (for large covers) was higher than or lower than the target range: 3.2V to 3.54V
  • Causes: • Cover Horizontal Registration Sensor: Large (S72) defective • D/A converter defective • A/D converter defective
  • Remedy:
  • Code: 795-47
  • Description: Book Exit Sensor (S64) Error PB (D391) The value for the adjustment of the book exit sensor was higher than or lower than the target range: 3.2V to 3.54V
  • Causes: • Signature exit sensor defective • D/A converter defective • A/D converter defective
  • Remedy:
  • Code: 795-48
  • Description: Leading Edge Sensor (S65) Error PB (D391) The value for the adjustment of the leading edge sensor was higher than or lower than the target range: 3.2V to 3.54V
  • Causes: • Leading edge sensor S65) defective • D/A converter defective • A/D converter defective
  • Remedy:
  • Code: 795-49
  • Description: Trim Unit Entrance Sensor (S92) Error PB (D391) The value for the adjustment of the sensor was out of range.
  • Causes: • Trim unit entrance sensor (S92) harness loose, broken, defective • Sensor defective
  • Remedy:
  • Code: 795-5
  • Description: Master-to-Inserter Board Communication Error PB (D391) Communication Error at Initialization After the ConfigSet (parallel signal) went ON while the inserter connection status was being checked, the initialization did not end successfully within 5 sec. The error time exceeded three times the maximum time allowed for the initialization communication (1.5 ms).
  • Causes: • Inserter board connector loose, broken, defective • Inserter board defective Bookbinder-to-Inserter Communication Error A command response for the inserter was not issued within the time prescribed for the timeout. There was an overflow in memory where information required for paper feed is stored. (Master control board detection.) • Inserter control board defective • Inserter control board connector loose, broken, defective Download Error The version of the firmware on the inserter control board could not be detected at power on. • Inserter control board defective • Inserter control board connector loose, broken, defective
  • Remedy:
  • Code: 795-50
  • Description: Book Registration Sensor (S88) Error PB (D391) The value for the adjustment of the book registration sensor was out of range.
  • Causes: • Slide motor (M44) connections loose, broken, defective • Motor defective • Book registration sensor (S88) harness loose, broken, defective • Sensor defective
  • Remedy:
  • Code: 795-51
  • Description: LE Detection Sensor (S65) Error PB (D391) No book could be detected in the path for trimming (the sensor could not detect a leading edge of a book).
  • Causes: • The book has slipped out of the grip of the book rotation plates
  • Remedy: