Description: Potential sensor error: Vd Adjustment M. The drum potential sensor detects 150V or more on the drum (Vd) for 0.7 msec. when the high voltage charge is supplied to the drum for the initial sampling before exposure.
Remedy: 1. Clean or replace the drum potential sensor. 2. Replace the drum unit.
Code: 423
Description: Potential sensor error: Vd Adjustment Y. The drum potential sensor detects 150V or more on the drum (Vd) for 0.7 msec. when the high voltage charge is supplied to the drum for the initial sampling before exposure.
Remedy: 1. Clean or replace the drum potential sensor. 2. Replace the drum unit.
Code: 424
Description: Potential sensor error: Vl adjustment K Vpl could not be adjusted to within ±5V of the target Vpl after exposure of the ID sensor patterns.
Remedy: 1. Clean or replace the drum potential sensor. 2. Replace the drum unit.
Code: 425
Description: Potential sensor error: Vl adjustment C Vpl could not be adjusted to within ±5V of the target Vpl after exposure of the ID sensor patterns.
Remedy: 1. Clean or replace the drum potential sensor. 2. Replace the drum unit.
Code: 426
Description: Potential sensor error: Vl adjustment M Vpl could not be adjusted to within ±5V of the target Vpl after exposure of the ID sensor patterns.
Remedy: 1. Clean or replace the drum potential sensor. 2. Replace the drum unit.
Code: 427
Description: Potential sensor error: Vl adjustment Y Vpl could not be adjusted to within ±5V of the target Vpl after exposure of the ID sensor patterns.
Remedy: 1. Clean or replace the drum potential sensor. 2. Replace the drum unit.
Code: 432
Description: Potential sensor error 1: Vr adjustment K Vr < –200V. The residual voltage (Vr), the amount of voltage that remains on the surface of the drum after the QL fires is less than –200V.
Remedy: 1. Clean or replace the drum potential sensor. 2. Replace the drum unit.
Code: 433
Description: Potential sensor error 2: Vr adjustment C Vr < –200V. The residual voltage (Vr), the amount of voltage that remains on the surface of the drum after the QL fires is less than –200V.