Description: Fan motor error
The machine does not lock for 3sec during rotating the fusing fan motor.
Causes: • Fan motor disconnected, defective • Fan motor harness loose, broken, defective
Code: 591
Description: PSU fan error
The machine does not lock for 3sec during rotating the PSU fan motor.
Causes: • Defective PSU fan
Code: 620
Description: GAVD communication error
The machine detects an error data of the ASIC.
Causes: • Defective engine board • Defective ASIC
Code: 622
Description: Paper tray unit communication error
Three consecutive errors occur during polling, after the paper tray unit is successful I2C communication.
Causes: • Disconnect harnesses
Code: 632
Description: Counter device error 1
After 3 attempts to send a data frame to the optional counter device via the serial communication line, no ACK signal was received within 100 ms.
Causes: • Serial line between the optional counter device, the relay board and copier control board is disconnected or damaged • Make sure that SP5113 is set to enable the optional counter device. 1. Check if the setting of the SP5113 is correctly set. 2. Check the connection between the main machine and optional counter device.
Code: 633
Description: Counter device error 2
After communication is established, the controller receives the brake signal from the accounting device.
Causes: • Serial line between the optional counter device, the relay board and copier control board is disconnected or damaged • Make sure that SP5113 is set to enable the optional counter device. 1. Check if the setting of the SP5113 is correctly set. 2. Check the connection between the main machine and optional counter device.
Code: 634
Description: Counter device error 3
A backup RAM error was returned by the counter device.
Causes: • Counter device control board defective • Backup battery of counter device defective Replace the counter device.
Code: 635
Description: Counter device error 4
A backup battery error was returned by the counter device.
Causes: • Counter device control board defective • Backup battery of counter device defective Replace the counter device.