Causes: • Module management is set for ON but the module was not recognized. • SDK application not recognized. • Module SD card defective, or recognition file corrupted • DESS (Data Encryption Security Service) module not present Note: DESS is the data encryption module built into the GW controller board.
Code: 641
Description: Engine to controller communication error
no answer
Causes: • Examine the connection between the controller and the engine board. • Replace the engine board if the error is frequent.
Code: 650
Description: Communication error of the remote service modem (Cumin-M)
Causes:
Code: 651
Description: Incorrect dial up connection
-001: Program parameter error -002: Program execution error
Causes: An unexpected error occurs when the modem (Cumin-M) tries to call the center with a dial up connection. • Caused by a software bug No action required because this SC does not interfere with operation of the machine.
Code: 652
Description: Remote service: ID2 confict
Causes:
Code: 653
Description: Remote service: ID2 fraudct
Causes:
Code: 669
Description: EEPROM Error
The EEPROM was not connected at power on, or read/write operations on the EEPROM failed.