Các lỗi thường gặp

Code :
  • Code: 365
  • Description: TD sensor (Vt low) error 2: M. The Vt value of the black, magenta, cyan, or yellow TD sensor is below the specified value with SP3020-004 (default: 0.5V) ten counts.
  • Causes: • TD sensor harness disconnected, loose, defective • A drawer connector disconnected, loose, defective • TD sensor defective
  • Remedy: 1. Check the black, magenta, cyan, or yellow TD sensor connector and harness between the TD sensor and development unit for damage. 2. Check the drawer connector of the PCDU. 3. Replace the PCDU.
  • Code: 366
  • Description: TD sensor (Vt low) error 2: C. The Vt value of the black, magenta, cyan, or yellow TD sensor is below the specified value with SP3020-004 (default: 0.5V) ten counts.
  • Causes: • TD sensor harness disconnected, loose, defective • A drawer connector disconnected, loose, defective • TD sensor defective
  • Remedy: 1. Check the black, magenta, cyan, or yellow TD sensor connector and harness between the TD sensor and development unit for damage. 2. Check the drawer connector of the PCDU. 3. Replace the PCDU.
  • Code: 367
  • Description: TD sensor (Vt low) error 2: Y. The Vt value of the black, magenta, cyan, or yellow TD sensor is below the specified value with SP3020-004 (default: 0.5V) ten counts.
  • Causes: • TD sensor harness disconnected, loose, defective • A drawer connector disconnected, loose, defective • TD sensor defective
  • Remedy: 1. Check the black, magenta, cyan, or yellow TD sensor connector and harness between the TD sensor and development unit for damage. 2. Check the drawer connector of the PCDU. 3. Replace the PCDU.
  • Code: 372
  • Description: TD sensor adjustment error: K. SC is issued only if one of followings is satisfied. • During TD sensor initialization, the output value of the black, magenta, cyan, or yellow TD sensor is not within the range of the specified value with SP3238-001 to -004 (default: 2.5V) ± 0.2V. • The TD sensor output is 0.7 V or more when the Vcnt is 4.3 v. • The adjusted Vcnt is 4.7 V or less.
  • Causes: • Heat seal not removed from a new developer pack • TD harness sensor disconnected, loose or defective • TD sensor defective • Harness between TD sensor and drawer disconnected, defective • Different developer density from initial developer density
  • Remedy: 1. Remove the heat seal from each PCDU. 2. Replace the PCDU.
  • Code: 373
  • Description: TD sensor adjustment error: M SC is issued only if one of followings is satisfied. • During TD sensor initialization, the output value of the black, magenta, cyan, or yellow TD sensor is not within the range of the specified value with SP3238-001 to -004 (default: 2.5V) ± 0.2V. • The TD sensor output is 0.7 V or more when the Vcnt is 4.3 v. • The adjusted Vcnt is 4.7 V or less.
  • Causes: • Heat seal not removed from a new developer pack • TD harness sensor disconnected, loose or defective • TD sensor defective • Harness between TD sensor and drawer disconnected, defective • Different developer density from initial developer density
  • Remedy: 1. Remove the heat seal from each PCDU. 2. Replace the PCDU.
  • Code: 374
  • Description: TD sensor adjustment error: C. SC is issued only if one of followings is satisfied. • During TD sensor initialization, the output value of the black, magenta, cyan, or yellow TD sensor is not within the range of the specified value with SP3238-001 to -004 (default: 2.5V) ± 0.2V. • The TD sensor output is 0.7 V or more when the Vcnt is 4.3 v. • The adjusted Vcnt is 4.7 V or less.
  • Causes: • Heat seal not removed from a new developer pack • TD harness sensor disconnected, loose or defective • TD sensor defective • Harness between TD sensor and drawer disconnected, defective • Different developer density from initial developer density
  • Remedy: 1. Remove the heat seal from each PCDU. 2. Replace the PCDU.
  • Code: 375
  • Description: TD sensor adjustment error: Y. SC is issued only if one of followings is satisfied. • During TD sensor initialization, the output value of the black, magenta, cyan, or yellow TD sensor is not within the range of the specified value with SP3238-001 to -004 (default: 2.5V) ± 0.2V. • The TD sensor output is 0.7 V or more when the Vcnt is 4.3 v. • The adjusted Vcnt is 4.7 V or less.
  • Causes: • Heat seal not removed from a new developer pack • TD harness sensor disconnected, loose or defective • TD sensor defective • Harness between TD sensor and drawer disconnected, defective • Different developer density from initial developer density
  • Remedy: 1. Remove the heat seal from each PCDU. 2. Replace the PCDU.
  • Code: 380
  • Description: Drum gear position sensor error: K. The machine does not detect a change signal (H L or L H) for 2.4 seconds at the drum phase adjustment.
  • Causes: • Dirty or defective drum gear position sensor
  • Remedy: 1. Check the harnesses. 2. Clean or replace the drum gear position sensor. 3. Replace the PCDU.