  • Code: 520
  • Description: 2nd paper tray cooling fan error (optional paper feed unit). The motor lock signal error from the cooling fan is detected for 10 seconds after turning on the cooling fan.
  • Causes: • Disconnected harness of the cooling fan • Defective cooling fan • Defective BCU
  • Remedy: 1. Check or replace the harness of the cooling fan. 2. Replace the cooling fan. 3. Replace the BCU.
  • Code: 521
  • Description: 3rd paper tray cooling fan error (optional paper feed unit). The motor lock signal error from the cooling fan is detected for 10 seconds after turning on the cooling fan.
  • Causes: • Disconnected harness of the cooling fan • Defective cooling fan • Defective BCU
  • Remedy: 1. Check or replace the harness of the cooling fan. 2. Replace the cooling fan. 3. Replace the BCU.
  • Code: 522
  • Description: 4th paper tray cooling fan error (optional paper feed unit). The motor lock signal error from the cooling fan is detected for 10 seconds after turning on the cooling fan.
  • Causes: • Disconnected harness of the cooling fan • Defective cooling fan • Defective BCU
  • Remedy: 1. Check or replace the harness of the cooling fan. 2. Replace the cooling fan. 3. Replace the BCU.
  • Code: 530
  • Description: Development fan 1 error. The motor lock signal error is detected for 10 seconds after the motor lock signal was first detected.
  • Causes: • Defective development fan 1 or development fan 2 • Disconnected or defective harness • Defective BCU
  • Remedy: 1. Check or replace the harness. 2. Replace the development fan 1 (SC530) or development fan 2 (SC531). 3. Replace the BCU.
  • Code: 531
  • Description: Development fan 2 error. The motor lock signal error is detected for 10 seconds after the motor lock signal was first detected.
  • Causes: • Defective development fan 1 or development fan 2 • Disconnected or defective harness • Defective BCU
  • Remedy: 1. Check or replace the harness. 2. Replace the development fan 1 (SC530) or development fan 2 (SC531). 3. Replace the BCU.
  • Code: 532
  • Description: Laser unit fan error The motor lock signal error is detected for 10 seconds after the motor lock signal was first detected.
  • Causes: • Defective laser unit fan • Disconnected or defective harness • Defective BCU
  • Remedy: 1. Check or replace the harness. 2. Replace the laser unit fan. 3. Replace the BCU.
  • Code: 533
  • Description: Fusing fan 2 error The motor lock signal error is detected for 10 seconds after the motor lock signal was first detected.
  • Causes: • Defective fusing fan 2 • Disconnected or defective harness • Defective BCU
  • Remedy: 1. Check or replace the harness. 2. Replace the fusing fan 2. 3. Replace the BCU.
  • Code: 534
  • Description: Fusing fan 1 error The motor lock signal error is detected for 10 seconds after the motor lock signal was first detected.
  • Causes: • Defective fusing fan 1 • Disconnected or defective harness • Defective BCU
  • Remedy: 1. Check or replace the harness. 2. Replace the fusing fan 1. 3. Replace the BCU.