Description: Thermal Pressure Motor Lock
• If the TPH Pressure switch has not been depressed within 4 seconds after the TPH Pressure motor was activated to lower the TPH.
• If the TPH Pressure switch has not been released within 4 seconds after the TPH Pressure motor was activated to raise the TPH.
Description: Elevator Motor Lock
• In 15 seconds from turning ON of the Elevator motor in upward direction, the Elevator upper limit sensor is not pushed.
• In 15 seconds from turning ON of the Elevator motor in downward direction, the light path of the Elevator lower limit sensor is not blocked.
• In 3 seconds from turning ON of the Elevator motor in upward direction, the Elevator lower sensor is held blocked.
• In 3 seconds from turning ON of the Elevator motor in downward direction, the Elevator upper limit sensor is held pressed down.
Description: Wing Motor Lock
• If neither of the Jump wing sw1 or sw2 has been depressed within 5 seconds after the Wing motor was activated.
• If neither of the Jump wing sw1 or sw2 has been released within 5 seconds after the Wing motor was activated.
Description: Clamp Error (1)
• In 4 seconds from turning ON of the Clamp solenoid in clamp retrial, the Clamp safety switch is held still pressed down.
• In 4 seconds from turning OFF of the Clamp solenoid, the Clamp safety SW has not been pressed.
• In 8 seconds from turning ON of the Clamp motor in opening direction in clamp retrial, the 180° Angular sensor has not detected magnet.
• In 8 seconds from turning ON of the Clamp motor in closing direction in clamp retrial, the 0° Angular sensor has not detected magnet.
In any of the above cases, master making is performed to the end.
Description: P. -F. Tray Slide Pulse Motor
• When the Paper feed tray position sensor is not turned on/ off within 165 pulses(approx. 3 second) after the P. -F. tray slide pulse motor is turned on.