Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Riso HC5000 — Trang 18/31

Code: 310 S96

Description: Cooling fan 2 not connected

Code: 311 S05

Description: Disconnection in head thermistor The head temperature could not be measured correctly. When the reading of the thermistor is -86.9 °C * Head identification information (K1 - Y6) is added after the error point.

Code: 312 S05

Description: Head abnormally hot The head temperature exceeded 80 °C. When the reading of the thermistor is 80.0 °C * Head identification information (K1 - Y6) is added after the error point.

Code: 313 S05

Description: Head cooling timeout The temperature remained above 45 °C for 10 minutes. When the monitored head temperature remains 45 °C or more for 10 minutes * Head identification information (K1 - Y6) is added after the error point.

Code: 314 S06

Description: Ink heating timeout When the temperature of ink in the distributor meets the following conditions after being heated for a set time: 1) & either 2), 3) 4), 5), 6) or 7) 1) The temperature is less than 15 °C. 2) It takes more than 360 seconds to raise the temperature by 1 °C after the heater has been powered on. 3) It takes more than 600 seconds to raise the temperature by 4 °C after the heater has been powered on. 4) It takes more than 750 seconds to raise the temperature by 7 °C after the heater has been powered on. 5) It takes more than 900 seconds to raise the temperature by 10 °C after the heater has been powered on. 6) It takes more than 1,320 seconds to raise the temperature by 13 °C after the heater has been powered on. 7) A temperature of less than 15 °C holds for more than 1,800 seconds. * Head identification information (K, C, M, Y) is added after the error point.

Code: 315 W99

Description: ID unit low liquid level Low liquid level is detected in the ID unit of each color ink. * Ink identification information (K, C, M, Y) is added after the error point.

Code: 316 S96

Description: Reservoir not connected * Ink identification information (K, C, M, Y) is added after the error point.

Code: 317 S96

Description: ID unit air open valve not connected * Ink identification information (K, C, M, Y) is added after the error point.