Mã lỗi Riso HC5000

Code: 001 S96

Description: Power supply remote signal not connected The control signal cable for the ON/OFF control of the 24/38-VDC output is disconnected. The signal wire grounded inside the power supply unit has been pulled up by the IP PCB to detect the level.

Code: 003 S97

Description: 38-VDC power supply voltage error A voltage drop is detected when a voltage drop is sensed by the IP PCB based on the signal resulting from dividing the 38-VDC resistance inside the power supply unit. The detection level is approximately 18 VDC. Voltage polling is conducted at 100-ms intervals by the IP-CPU. An error is detected when a voltage drop is sensed 10 times in succession (approx. 1 sec). No detection is performed when the interlock SW is open.

Code: 004 S97

Description: 24-VDC power supply voltage error A voltage drop is detected when a voltage drop is sensed by the IP PCB based on the signal resulting from dividing the 24-VDC resistance inside the power supply unit. The detection level is approximately 11 VDC. Voltage polling is conducted at 100-ms intervals by the IP-CPU. An error is detected when a voltage drop is sensed 10 times in succession (approx. 1 sec). No detection is performed when the interlock SW is open.

Code: 006 S97

Description: 3.3-VDC power supply voltage error A voltage drop is detected when a voltage drop is sensed in the 3.3-VDC power supply on the MIP side of the IP PCB. Voltage polling is conducted at 100-ms intervals by the IP-CPU. An error is detected when a voltage drop is sensed 10 times in succession (approx. 1 sec).

Code: 007 S97

Description: 1.8-VDC power supply voltage error A voltage drop is detected when a voltage drop is sensed in the 1.8-VDC power supply on the MIP side of the IP PCB. Voltage polling is conducted at 100-ms intervals by the IP-CPU. An error is detected when a voltage drop is sensed 10 times in succession (approx. 1 sec).

Code: 008 S96

Description: Control panel not connected The absence of the control panel unit to be connected to the MC PCB is detected. Since this configuration lacks this panel, this error indication will not be issued under normal operating circumstances.

Code: 009 S96

Description: Print counter not connected The absence of a print counter is detected.

Code: 011 S96

Description: CIS PCB not connected The connection of the CIS PCB cannot be confirmed.