Code: P01-538

Description: Print drum is not locked during operation. (Print-drum lock position sensor: OFF)

Code: P02-400

Description: Both the upper and lower limit sensors were ON at the same time.

Code: P02-401

Description: Overload current was detected in the elevator motor.

Code: P02-404

Description: The lower-limit sensor does not go OFF within 2 seconds after the elevator motor operates in the raising direction from the lower-limitposition.

Code: P02-405

Description: The upper-limit sensor does not go ON within 12 seconds after the elevator motor operates in the raising direction.

Code: P02-406

Description: The upper-limit sensor does not go OFF within 2 seconds after the elevator motor operates in the lower direction from the upper-limitposition.

Code: P02-407

Description: The lower-limit sensor does not go ON within 12 seconds after the elevator motor operates in the lowering direction.

Code: P02-408

Description: The upper-limit sensor is OFF continuously for over 2 seconds during operation of the elevator servo action to raise the feed tray.