Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Roland AJ1000 — Trang 2/6

Code: 0107

Description: Linear Encoder Setup has not been done.
Causes: Linear Encoder Setup has not been done.

Code: 0110

Description: Input value from Linear Encoder is not changed when Linear Encoder is setup the origin. When Motor stops during printing, Motor does not complete the movement which is supposed to be done.
Causes: Read error of Linear Encoder. Read error of Encoder on Scan Motor side. Wire is not fixed to Head Carriage firmly.?

Code: 0120

Description: There is a problem with Thermistor for Pre-Heater F.
Causes: Device has a problem. Thermistor Cable has short circuited or cutline.

Code: 0121

Description: There is a problem with thermistor for Pre-Heater R.
Causes: Device has a problem. Thermistor Cable has short circuited or cutline.

Code: 0125

Description: Heater is unusually hot. Pre-Heater F temperature has reached 60°C and above.
Causes: Heater Cable connection has a problem. Thermostat has a problem (not working). Thermistor has a problem.

Code: 0126

Description: Heater is unusually hot. Pre-Heater F temperature has reached 60°C and above.
Causes: Heater Cable connection has a problem. Thermostat has a problem (not working). Thermistor has a problem.

Code: 0130

Description: There is a problem with Thermistor for Print Heater.
Causes: Device has a problem. Thermistor Cable has short circuited or cutline.

Code: 0135

Description: Heater is unusually hot. Print Heater temperature has reached 60°C and above.
Causes: Heater Cable connection has a problem. Thermostat has a problem (not working). Thermistor has a problem.