Code: 0171

Description: Even though the machine carries out the regular movement, the output of Supply Pump 2 Sensor does not reach the expected value.
Causes: Supply Pump 2 Motor has a problem. Supply Pump 2 Sensor has a problem. Supply Pump 2 Magnet has dropped out. Wiring or Flexible Cable has short circuitted or cut-line. Pump Drive Board has a problem. Servo Board has a problem.

Code: 0172

Description: Even though the machine carries out the regular movement, the output of Supply Pump 3 Sensor does not reach the expected value.
Causes: Supply Pump 3 Motor has a problem. Supply Pump 3 Sensor has a problem. Supply Pump 3 Magnet has dropped out. Wiring or Flexible Cable has short circuitted or cut-line. Pump Drive Board has a problem. Servo Board has a problem.

Code: 0173

Description: Even though the machine carries out the regular movement, the output of Supply Pump 4 Sensor does not reach the expected value.
Causes: Supply Pump 4 Motor has a problem. Supply Pump 4 Sensor has a problem. Supply Pump 4 Magnet has dropped out. Wiring or Flexible Cable has short circuitted or cut-line. Pump Drive Board has a problem. Servo Board has a problem.

Code: 0174

Description: Even though the machine carries out the regular movement, the output of Supply Pump 5 Sensor does not reach the expected value.
Causes: Supply Pump 5 Motor has a problem. Supply Pump 5 Sensor has a problem. Supply Pump 5 Magnet has dropped out. Wiring or Flexible Cable has short circuitted or cut-line. Pump Drive Board has a problem. Servo Board has a problem.

Code: 0175

Description: Even though the machine carries out the regular movement, the output of Supply Pump 6 Sensor does not reach the expected value.
Causes: Supply Pump 6 Motor has a problem. Supply Pump 6 Sensor has a problem. Supply Pump 6 Magnet has dropped out. Wiring or Flexible Cable has short circuitted or cut-line. Pump Drive Board has a problem. Servo Board has a problem.

Code: 0180

Description: Even though the machine carries out the regular movement, the output of Maintenance Liquid Pump Sensor does not reach the expected value.
Causes: Maintenance Liquid Pump Motor has a problem. Maintenance Liquid Pump Sensor has a problem. Maintenance Liquid Pump Magnet has dropped out. Wiring or Flexible Cable has short circuitted

Code: 0190

Description: Thermistor under the BED has a problem.
Causes: Device has a problem. Thermistor Cable has short circuited or cutline.

Code: 0200

Description: Head 1 is abnormally hot. Head 1 temperature has reached 58°C and above.
Causes: Thermistor (Head) has a problem. Flexible Cable has short circuitted or cut-line. Wiring of Head Heater has a problem.