Description: Linear Encoder Setup has not been done.
Causes: Linear Encoder Setup has not been done.
Description: Input value from Linear Encoder is not changed when Linear Encoder is setup the origin. When Motor stops during printing, Motor does not complete the movement which is supposed to be done.
Causes: Read error of Linear Encoder. Read error of Encoder on Scan Motor side. Wire is not fixed to Head Carriage firmly.?
Description: There is a problem with Thermistor for Pre-Heater F.
Causes: Device has a problem. Thermistor Cable has short circuited or cutline.
Description: There is a problem with thermistor for Pre-Heater R.
Causes: Device has a problem. Thermistor Cable has short circuited or cutline.
Description: Heater is unusually hot. Pre-Heater F temperature has reached 60°C and above.
Causes: Heater Cable connection has a problem. Thermostat has a problem (not working). Thermistor has a problem.
Description: Heater is unusually hot. Pre-Heater F temperature has reached 60°C and above.
Causes: Heater Cable connection has a problem. Thermostat has a problem (not working). Thermistor has a problem.
Description: There is a problem with Thermistor for Print Heater.
Causes: Device has a problem. Thermistor Cable has short circuited or cutline.
Description: Heater is unusually hot. Print Heater temperature has reached 60°C and above.
Causes: Heater Cable connection has a problem. Thermostat has a problem (not working). Thermistor has a problem.