  • Code: 10-015
  • Display: S: Sensor Failure T: Humidity sensor has problem #10-015 Turn off then on
  • Description: There are some effective humidity range(Min-Max) on product. - Humidity Out error occurs when Humidity value is under the minimum. - Humidity Open error occurs when Humidity value is over the maximum.
  • Remedy: 1. Check the CN19 connector on Main-PBA.
  • Code: 10-016
  • Display: S: Sensor Failure T: Humidity sensor has problem #10-016 Turn off then on
  • Description: There are some effective humidity range(Min-Max) on product. - Humidity Out error occurs when Humidity value is under the minimum. - Humidity Open error occurs when Humidity value is over the maximum.
  • Remedy: 1. Check the CN19 connector on Main-PBA.
  • Code: 10-017
  • Display: S: Sensor Failure T: Inner temperature sensor Failure #10-017 Turn off then on
  • Description: inner temperature circuit is open. please reboot the machine.
  • Remedy: 1. Check the CN19 connector on Main-PBA.
  • Code: 10-018,10-019
  • Display: S: Sensor Failure T: Inner temperature sensor Failure #-019 Turn off then on
  • Description: inner temperature circuit is short. please reboot the machine.
  • Remedy: 1. Check the CN19 connector on Main-PBA.
  • Code: 11
  • Display: S: [O] toner is empty T: [OO] toner is empty. Replace with new one
  • Description: The lifespan of the toner cartridge which the arrow indicates is reached
  • Remedy: Replace the new toner cartridge.
  • Code: 12
  • Display: S: [O] toner Not Installed T: [OO] toner cartridge is not installed. Install it
  • Description: The toner cartridge is not installed or the CRUM (Consumer Replaceable Unit Monitor) in the cartridge is not properly connected
  • Remedy: 1. Take out the toner cartridge and re-install it. 2. If the problem persists, check the CN24 connector on Main-PBA. 3. Check the connector, harness of the DEVE CRUM IF PBA.
  • Code: 13
  • Display: S: [O] Not Compatible T: [OO] toner cartridge is not compatible. Check guide
  • Description: The toner cartridge you have installed is not for your machine.
  • Remedy: 1. Check the samsung-genuine toner cartridge is installed or not. 2. Check the CN24 connector on Main-PBA. 3. Check the connector, harness of the DEVE CRUM IF PBA.
  • Code: 14
  • Display: S: [O] toner is worn T: [OO] toner is worn. Replace with new one
  • Description: The color toner cartridge has run out. The machine stops printing.
  • Remedy: You can select the option among Stop, Continue or Black Only.If you select Stop, the machine stops printing. If you select Continue, the machine keeps printing, but the quality cannot be guaranteed. If you select Black Only, the machine prints the data in black. If you do not select any, the machine will work as Stop is selected.Replace the toner cartridge with a Samsung-genuine toner cartridge.