Remedy: 1. If the actuator fuser sensing part has some problems, replace the actuator fuser and exit sensor. 2. Reconnect the CN6 connector on HVPS. 3. Reconnect connector of CN1,2 on HVPS and check the flat cable.
Code: 08
Display: Jam of duplex
Description: Paper jammed in the duplex area.
Remedy: 1. Open the Front Cover and separate the PTB unit. Remove the Jammed paper. 2. If the paper is not reached to the duplex path after the exit sensor sensing, check the Clutch-BK deve. If it is defective, replace it.
Code: 09
Display: S: Output bin Full T: Output bin Full. Remove printed paper
Description: The paper is full on exit tray.
Remedy: 1. Clear the paper on exit tray. 2. Reconnect the CN3 connector on Main-PBA. 3. Replace the Actuator-Stacker and Actuator-OutFull. * Actuator-Stacker (JC66-02065A) * Actuator-Outfull (JC66-02064A) * Photo-Interrupter (0604-001095)
Code: 10
Display: S: [O] toner is Low T: [O] toner is low. Order new one
Description: The toner cartridge is almost empty
Remedy: Prepare the new toner cartridge.
Code: 10-004
Display: S: System error T: Error: #10-004 Turn off then on
Description: The communication error occurred.
Remedy: 1. Check the OPE PBA connection. If the harness is properly not connected to OPE PBA, re-connect it. 2. If the problem persists, replace the OPE PBA. 3. Replace the Main PBA.
Code: 10-012
Display: S: Sensor Failure T: Temperature sensor has Problem #10-012. Turn off then on
Description: There is a problem in the sensor signal.
Remedy: 1. Check the CN19 connector on Main-PBA. 2. Replace the Main-PBA.
Code: 10-013
Display: S: Sensor Failure T: Outer temperature sensor Failure #10-013 Turn off then on
Description: There are some effective Outer Temperature sensor value range(Min-Max) on product. - Outer Temp.Short error occurs when Outer Temperature sensor value is under the minimum. - Outer Temp.Open error occurs when Outer Temperature sensor value is over the maximum.
Remedy: 1. Check the CN19 connector on Main-PBA.
Code: 10-014
Display: S: Sensor Failure T: Outer temperature sensor Failure #10-014 Turn off then on
Description: There are some effective Outer Temperature sensor value range(Min-Max) on product. - Outer Temp.Short error occurs when Outer Temperature sensor value is under the minimum. - Outer Temp.Open error occurs when Outer Temperature sensor value is over the maximum