Display: Fuser Error :#02-000 Please turn off then on.
Description: At Warm-up, this error has occurred. The machine does not work until power off/on. If the error code reoccurs, follow the Troubleshooting method below
Causes: Fuser Unit is not installed and AC is not supplied to the Heat Lamp.
Code: 02-001, 02-006
Display: Fuser Error :#02-001 Please turn off then on. Fuser Error :#02-006 Please turn off then on.
Description: At Warm-up, this error has occurred. The machine does not work until power off/on. If the error code reoccurs, follow the Troubleshooting method below.
Causes: Fuser Unit is not installed and AC is not supplied to the Heat Lamp.
Code: 02-002
Display: System Error :#02-002 Please turn off then on.
Description: The fuser unit is overheated. The machine does not work until power off/on. If the error code reoccurs, follow the Troubleshooting method below.
Causes: The machine can not control fuser temperature.
Code: 02-005
Display: System Error :#02-005 Please turn off then on.
Description: The ADC port is short.
Causes: The machine can not control fuser temperature.
Code: 03-000
Display: Motor error Error: #03-000 Turn off then on
Description: Motor Signal is abnormal.
Causes: 1. Harness is defective, Connector is not connected properly. 2. Main BLDC Motor is defective. 3. Main Board is defective.
Code: 03-007, 03-008, 03-009
Display: Motor error Error: #03-007/008/009 Turn off then on
Description: Motor Signal is abnormal.
Causes: 1. Harness is defective, Connector is not connected properly. 2. Color OPC BLDC Motor is defective. 3. Main Board is defective.
Code: 03-015
Display: Motor error Error: #03-015 Turn off then on
Description: Fan does not operate.
Causes: Fan is defective.
Code: 04-001, 04-002, 04-008
Display: LSU error: #. Please turn off then on.A.
Description: Laser beam detect signal has not occurred or is irregular. LSU motor does not operate.
Causes: 1. Harness is defective, Connector is not connected properly. 2. LSU is defective. 3. Main Board is defective.