Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Sharp AL1621 — Trang 5/7

Code: H2-00

Description: Thermistor open detection
Fusing thermistor open
Causes: Thermistor defect MCU PWB defect Fusing section connector contact failure Power failure Fusing unit not installed
Remedy: Check the harness and the connector of the thermistor and the MCU. Clear the self diag display with SIM 14.

Code: H3-00

Description: Heat roller abnormally high temperature
Fusing temperature of 220 ~ 240°C.
Causes: Thermistor defect MCU PWB defect Fusing connector connection failure Power failure
Remedy: Check the heater lamp blinking with SIM 5-2. When the lamp blinks normally: Check the thermistor and the harness. Check the MCU PWB thermistor input circuit. When the lamp lights up instead of blinking: Check the lamp control circuit of the power PWB and the MCU PWB.

Code: H4-00

Description: Heat roller abnormally low temperature
When the temperature does not reach 155°C within 55 sec after turning on the power, or when it falls under 145°C during printing, or when it falls under 100°C during pre-heating.
Causes: Thermistor failure Heater lamp failure MCU PWB failure Thermostat failure Power failure Interlock switch failure
Remedy: Check blinking of the heater lamp with SIM 5-2. When the lamp blinks normally: Check the thermistor and the harness. Check the MCU PWB thermistor input circuit. When the lamp does not light: Check for heater lamp disconnection or thermostat disconnection. Check the interlock switch. Check the power PWB and MCU PWB lamp control circuit. Clear the trouble with SIM 14.

Code: L1-00

Description: Mirror base feed trouble
The mirror home position (MHPS) does not turn off though the feed operation is completed during mirror initial operation after turning on the power. The mirror home position (MHPS) does not turn off during shading operation. The mirror home position (MHPS) does not turn on when the mirror base is returned for the specified time after copy feed is started and SPF scanning position shift is performed.
Causes: Mirror unit defect Mirror home position sensor defect MCU PWB decfect Scanner wire disconnection
Remedy: Check the scanning operation with SIM 1-1.

Code: L3-00

Description: Mirror base return trouble
The mirror home position (MHPS) does not turn on though the mirror base returning is completed during mirror initial operation after turning on the power. The mirror home position does not turn on when the mirror is returned to the home position during shading. The mirror home position (MHPS) does not turn on when the mirror base returning is completed for the specified time (about 6 sec) after copy return start.
Causes: Mirror unit Mirror home position sensor defect MCU PWB defect Scanner wire disconnection
Remedy: Check the scanning operation with SIM 1-1.

Code: L4-01

Description: Main motor lock
The main motor encoder pulse is not detected for 400msec.
Causes: Main motor defect Harness disconnection between the MCU PWB and the main motor. Control circuit failure
Remedy: Check the main motor operation with SIM 25-1. Check the harness and the connector between the MCU PWB and the main motor.

Code: L4-10

Description: Job separator motor abnormality
Causes:
Remedy:

Code: L6-10

Description: Polygon motor lock
The lock signal (the specified rotation speed signal) is not supplied within the specified time (about 6 sec)after starting the polygon motor rotation.
Causes: LSU connector disconnection or harness disconnection in the LSU.
Remedy: Check the operation of the polygon motor with SIM 25-10. Check the harness and the connector connection. LSU replacement
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie