Remedy: Check that the EEPROM is properly set. To prevent against loss of counter/adjustment values, record the values with simulation. U2 trouble cancel with SIM 16 MCU PWB replacement
Description: Counter check sum error
Counter check sum value stored in the EEPROM is abnormal.
Causes: EEPROM failure Control circuit hung up by noises MCU PWB EEPROM access circuit defect
Remedy: Check that the EEPROM is properly set. To prevent against loss of counter/adjustment values, record the values with simulation. U2 trouble cancel with SIM 16 MCU PWB replacement
Description: Adjustment value check sum error (EEPROM)
Adjustment value data area check sum error
Causes: EEPROM failure Control circuit hung up by noises MCU PWB EEPROM access circuit failure
Remedy: Check that the EEPROM is properly set. To prevent against loss of counter/adjustment values, record the values with simulation. U2 trouble cancel with SIM 16 MCU PWB replacement
Description: Operation control PWB communication trouble
Communication setup error, framing, parity, protocol error
Causes: Operation control PWB connector disconnection Operation control PWB MCU PWB harness failure
Remedy: Check the connectors and harness of the operation control PWB and the MCU PWB. Check grounding of the machine. Check the ROM of the operation control PWB.