Mã lỗi Sharp AR285 — Trang 3/11
Code:
Tất cả lỗi (87)
C1 00
C2 00
E7 00
E7 01
E7 02
E7 03
E7 10
E7 11
E7 13
E7 90
EE EL
EE EU
F1 00
F1 01
F1 02
F1 03
F1 04
F1 05
F1 06
F1 08
F1 10
F1 11
F1 14
F1 15
F1 16
F1 17
F1 18
F1 50
F1 80
F2 00
F2 02
F2 31
F2 32
F2 37
F2 39
F3 12
F3 22
F9 00
F9 01
F9 03
F9 04
F9 10
F9 90
FC 00
FC 01
H2 00, H2 HL1
H2 01, H2 HL2
H3 00, H3 HL1
H3 01, H3 HL2
H4 00, H4 HL1
H4 01, H4 HL2
H5 01
H5 02
L1 00
L3 00
L4 01
L6 10
L8 01
L8 02
PF 00
U2 00
U2 11
U2 12
U4 02
U4 03
U5 00
U5 01
U5 02
U5 03
U5 06
U5 07
U5 08
U5 11
U5 16
U6 00
U6 01, U6 02, U6 03
U6 08
U6 09
U6 10
U6 20
U6 21
U6 22
U6 50
U6 51
U7 00
U9 00
U9 90
Description: Finisher 1 elevator lower limit detection/ Finisher 2 stack tray lower limit detection. When the bin is shifted, the upper limit or the lower limit sensor is detected. / The elevator exceeds the lower limit.
Causes: Sensor defective Sorter/finisher control PWB abnormality
Remedy: Check sensor with SIM3-2.
Description: Finisher 1 elevator home / Finisher 2 stack tray sensor abnormality. The elevator does not detect the home position. / Stack tray sensors are turned on in the abnormal combination.
Causes: Sensor defective Sorter/finisher control PWB abnormality
Remedy: Check sensor with SIM3-2.
Description: Finisher shift motor abnormality. 1) Bin shift is not completed within 2.5 seconds after bin shift request
Causes: Motor lock Improper motor speed Overcurrent to motor Finisher control PWB defective
Remedy: Check bin shift motor operation with SIM3-4.
Description: Finisher staple shift motor trouble. Staple motor drive trouble
Causes: Motor lock Motor rpm abnormality Overcurrent to motor Finisher control PWB trouble
Remedy: Check the operation of the staple motor with SIM 3-3.
Description: Finisher staple unit operation trouble. Staple operation trouble
Causes: Motor lock Motor rpm abnormality Motor overcurrent Finisher control PWB trouble
Remedy: Check the staple motor operation with SIM 3-3.
Description: Finisher 1 pusher motor trouble / Finisher 2 boomerang rotation abnormality. Pusher motor trouble / Paddle solenoid abnormality
Causes: Motor lock / paddle solenoid operation abnormality / boomerang rotation sensor abnormality Motor rpm abnormality Motor overcurrent Finisher control PWB abnormality
Remedy: Check the finisher motor operation, the paddle solenoid operation with SIM 3-3 or check the boomerang rotation sensor with SIM 3-2.
Description: Finisher 2 stack tray abnormality. Stack tray control sensor abnormality
Causes: The paper surface sensor and the full stack sensor do not turn on even when a certain time is passed after starting the tray.
Remedy: Check the sensor operation with SIM 3-2.
Description: Finisher 1 elevator motor trouble / Finisher 2 stack tray motor lock. Elevator motor trouble
Causes: Motor lock Motor rpm abnormality Motor overcurrent Finisher control PWB trouble
Remedy: Check the elevator motor operation with SIM 3-3.