Remedy: Case 1 Cause Battery life Check & Remedy Check to insure that the battery voltage is about 2.5V or above. Case 2 Cause Battery circuit abnormality. Check & Remedy Check the battery circuit.
Causes: Abnormal value is read from the RTC on the ICU PWB.
Remedy: Case 1 Cause RTC circuit abnormality Check & Remedy Set the time again with the key operation, and check that time advances properly. Check the RTC circuit. Case 2 Cause Battery voltage fall. Battery circuit abnormality. Check & Remedy Check to insure that the battery voltage is about 2.5V or above. Check the battery circuit.
Remedy: Case 1 Cause EEPROM trouble. EEPROM is not initialized. Check & Remedy 1. Check that the EEPROM is properly set. 2. Use SIM 16 to cancel the error. Case 2 Cause ICU PWB EEPROM access circuit trouble Check & Remedy 1. To prevent against deletion of the counter data and the adjustment data, record them with the simulation. (When a printer option is installed, use SIM 22-1 to record the counter data and the adjustment data.) 2. Replace the ICU PWB. 3. Use SIM 16 to cancel the error.
Description: EEPROM check sum error (ICU detection)
Causes: EEPROM (ICU) check sum error
Remedy: Case 1 Cause EEPROM trouble Check & Remedy 1. Check that the EEPROM is properly set. 2. Use SIM 16 to cancel the error. Case 2 Cause Control circuit freeze by noises. ICU PWB EEPROM access circuit trouble. Check & Remedy 1. To prevent against deletion of the counter data and the adjustment data, record them with the simulation. (When a printer option is installed, use SIM 22-1 to record the counter data and the adjustment data.) 2. Replace the ICU PWB. 3. Use SIM 16 to cancel the error.
Description: FAX backup SRAM memory check sum error
Causes: FAX backup SRAM memory check sum error
Remedy: Case 1 Cause SRAM trouble Check & Remedy Initialize the one-touch dial and the FAX soft switch registered in the SRAM. Cancel the trouble with SIM 16. Case 2 Cause Control circuit freeze by noises. Access circuit trouble. Check & Remedy Replace the FAX PWB. Use SIM 16 to cancel the error.
Description: Production No. data discrepancy (ICU - PCU)
Causes: The production No. recorded in the PCU differs from that recorded in the ICU.
Remedy: Case 1 Cause EEPROM is not exchanged when replacing the PCU/ ICU PWB. Check & Remedy Check that the EEPROM is properly installed. When replacement, check that the EEPROM before replacement is inserted to the board after replacement.
Remedy: Case 1 Cause EEPROM trouble, Insertion of EEPROM which is not initialized or defective. Check & Remedy 1. Check that the EEPROM is properly inserted. 2. Use SIM 16 to cancel the error. Case 2 Cause SCN PWB EEPROM access circuit trouble Check & Remedy 1. To prevent against deletion of the counter data and the adjustment data, record them with the simulation. (When a printer option is installed, use SIM 22-1 to record the counter data and the adjustment data.) 2. Replace the SCN PWB. 3. Use SIM 16 to cancel the error.
Description: Adjustment value check sum error (SCN)
Causes: EEPROM (SCN) check sum error
Remedy: Case 1 Cause EEPROM trouble Check & Remedy 1. Check that the EEPROM is properly inserted. 2. Use SIM 16 to cancel the error. Case 2 Cause SCN PWB EEPROM access circuit trouble Check & Remedy 1. To prevent against deletion of the counter data and the adjustment data, record them with the simulation. (When a printer option is installed, use SIM 22-1 to record the counter data and the adjustment data.) 2. Replace the SCN PWB. 3. Use SIM 16 to cancel the error.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.