Description: Adjustment value check sum error (Controller) Adjustment data area check sum error
Causes: EEPROM trouble Control circuit trouble by noise Controller PWB EEPROM access circuit trouble
Remedy: Check that EEPROM is properly inserted. Save the counter/adjustment values with the DIAG simulation. Use DIAG (SIM16) to cancel U2 trouble. Replace the Controller PWB.
Causes: EEPROM abnormality EEPROM which is not initialized is installed. Hang of control circuit due to noises Scanner PWB EEPROM access circuit abnormality
Remedy: Check that EEPROM is set properly. Record counter/adjustment values with the simulation to protect the data from being deleted. Cancel U2 trouble with SIM 16. Replace scanner PWB.
Description: Memory check sum error (Scanner) Scanner memory check sum error
Causes: EEPROM trouble Control circuit freeze by noises Scanner PWB EEPROM access circuit trouble
Remedy: Check that EEPROM is set properly. Record counter/adjustment values with the simulation to protect the data from being deleted. Cancel U2 trouble with SIM 16. Replace scanner PWB.
Causes: EEPROM trouble EEPROM is not initialized. Hang of control circuit due to noises PCU PWB EEPROM access circuit trouble
Remedy: Check that EEPROM is properly inserted. Save the counter/adjustment values with the DIAG simulation. Use DIAG (SIM16) to cancel U2 trouble. Replace the Controller PWB.
Description: Memory check sum error (PCU) PCU memory check sum error
Causes: EEPROM trouble EEPROM is not initialized. PCU PWB EEPROM access circuit trouble Uninitialized EEPROM installed.
Remedy: Check that EEPROM is properly inserted. Save the counter/adjustment values with the DIAG simulation. Use DIAG (SIM16) to cancel U2 trouble. Replace the Controller PWB.