Mã lỗi Sharp ARM350 — Trang 7/12
Code:
Tất cả lỗi (91)
C1-00
CE-00
CE-01
CE-02
CE-03
CE-04
CE-05
E6-10
E6-11
E6-14
E7-02
E7-03
E7-06
E7-10
E7-11
E7-14
E7-50
E7-80
E7-90
EE-EL
EE-EU
F1-00
F1-00
F1-02
F1-02
F1-03
F1-06
F1-08
F1-10
F1-10
F1-11
F1-11
F1-12
F1-12
F1-15
F1-19
F1-20
F1-20
F1-30
F1-31
F1-32
F1-33
F1-34
F1-35
F1-36
F1-37
F1-38
F1-80
F1-80
F1-81
F1-87
F2-00
F2-02
F2-04
F2-05
F2-39
F3-12
F3-22
F6-00
F6-01
F6-04
F7-01
F9-02
F9-03
H2-xx
H3-xx
H4-xx
H5-01
L1-00
L3-00
L4-01
L4-02
L6-10
L8-01
L8-02
PF-00
U1-01
U102
U2-00
U2-11
U2-12
U2-80
U2-81
U2-90
U2-91
U6-00
U6-01
U6-02
U6-03
U6-10
U7-00
Description: Mail-bin stacker (AR-MS1) power abnormality The 24V power is not supplied to the Mail-bin stacker PWB.
Causes: Improper connection or disconnection of connector and harness Mail-bin stacker control PWB trouble Power unit (AR-DC1) trouble
Remedy: Use DIAG (SIM3-20) to check the sensor operation.
Description: Console finisher transport motor abnormality Transport motor trouble
Causes: Motor lock Motor rpm abnormality Overcurrent to the motor Console finisher control PWB trouble
Remedy: Use DIAG (SIM3-3) to check the motor operation.
Description: Finisher (AR-FN6) staple rotation motor trouble Front staple rotation motor trouble
Causes: Motor lock Motor rpm abnormality Overcurrent to the motor Finisher control PWB trouble
Remedy: Use DIAG (SIM3-3) to check the motor operation
Description: Toner control sensor abnormality Toner control sensor output open
Causes: Connector harness trouble Connector disconnection
Remedy: Check connection of the toner control sensor. Check connection of connector and harness to the main PWB. Check for disconnection of harness.
Description: Toner supply abnormality Toner control sensor output value becomes under-toner too earlier.
Causes: Connector harness trouble Toner control sensor trouble The toner cartridge seal is not removed
Remedy: Check connection of the connector in the toner motor section. Check connection of connector and harness to the main PWB. Check for disconnection of harness. Toner control sensor output check DIAG (SIM25-1) Remove the toner cartridge seal.
Description: Improper cartridge (life cycle error, etc.) An improper process cartridge is inserted.
Causes: IC chip trouble Improper cartridge
Remedy: IC chip trouble Improper cartridge
Description: CRUM error Communication with IC chip cannot be made.
Causes: IC chip trouble Improper cartridge
Remedy: Insert a proper cartridge.
Description: Process thermistor trouble Process thermistor open
Causes: Process thermistor trouble Process thermistor harness disconnection PCU PWB trouble
Remedy: Check connection of harness and connector of the process thermistor. Check PCU PWB.