Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Sharp ARP350 — Trang 8/9

Code: L8 01

Description: No fullwave signal. Full wave signal is not detected.
Causes: The PCU PWB connector or the power unit harness is disconnected or broken. PCU PWB trouble Power unit trouble
Remedy: Check connection of the harness and connector. Replace PCU PWB. Replace the power unit.

Code: L8 02

Description: Full wave signal width abnormality. It is judged as frequency abnormality of full wave signal. (When the detection cycle is judged as 69Hz or above or 42.5Hz or below)
Causes: The connector or harness of the PCU PWB and the power PWB is disconnected. PCU PWB trouble Power unit trouble
Remedy: Check connection of the harness and connector. Replace the PCU PWB. Replace the power unit.

Code: PF 00

Description: RIC copy inhibit signal is received. Copy inhibit command from RIM (host) is received.
Causes: Judged by the host.
Remedy: Inform to the host.

Code: U1 01

Description: Backup SRAM battery voltage fall
Causes: Battery life Battery circuit abnormality
Remedy: Check that the battery voltage is about 2.5V or above. Check the battery circuit.

Code: U2 00

Description: EEPROM read/write error (Controller). EEPROM write error
Causes: EEPROM trouble EEPROM is not initialized. Controller PWB EEPROM access circuit trouble
Remedy: Check that EEPROM is properly inserted. Save the counter/adjustment values with the DIAG simulation. Use DIAG (SIM16) to cancel U2 trouble. Replace the Controller PWB.

Code: U2 11

Description: Counter check sum error (Controller). Counter data area check sum error
Causes: EEPROM trouble Control circuit trouble by noise Controller PWB EEPROM access circuit trouble
Remedy: Check that EEPROM is properly inserted. Save the counter/adjustment values with the DIAG simulation. Use DIAG (SIM16) to cancel U2 trouble. Replace the Controller PWB.

Code: U2 12

Description: Adjustment value check sum error (Controller)
Causes: EEPROM trouble Control circuit trouble by noise Controller PWB EEPROM access circuit trouble
Remedy: Check that EEPROM is properly inserted. Save the counter/adjustment values with the DIAG simulation. Use DIAG (SIM16) to cancel U2 trouble. Replace the Controller PWB.

Code: U2 90

Description: PCU EEPROM write error
Causes: EEPROM trouble EEPROM is not initialized. PCU PWB EEPROM access circuit trouble
Remedy: Check that EEPROM is properly inserted. Save the counter/adjustment values with the DIAG simulation. Use DIAG (SIM16) to cancel U2 trouble. Replace the Controller PWB.
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie