Các lỗi thường gặp

Code :
  • Code: L4-35
  • Description: Fusing exhaust fan lock
  • Causes: When the fusing exhaust fan is operated, the fan operation signal is not detected within the specified time.
  • Remedy: Case 1 Cause Fan connector disconnection Check and remedy Check the harness and the connector between the PCU PWB and the fan. Case 2 Cause Fan does not rotate because of other trouble. Check and remedy Use SIM6-2 to check that the fan is actually rotating.
  • Code: L4-36
  • Description: Fusing suction fan lock
  • Causes: When the fusing suction fan is operated, the fan operation signal is not detected within the specified time.
  • Remedy: Case 1 Cause Fan connector disconnection Check and remedy Check the harness and the connector between the PCU PWB and the fan. Case 2 Cause Fan does not rotate because of other trouble. Check and remedy Use SIM6-2 to check that the fan is actually rotating.
  • Code: L4-38
  • Description: Machine ventilation fan center lock
  • Causes: When the machine ventilation fan center is operated, the fan operation signal is not detected within the specified time.
  • Remedy: Case 1 Cause Fan connector disconnection Check and remedy Check the harness and the connector between the PCU PWB and the fan. Case 2 Cause Fan does not rotate because of other trouble. Check and remedy Use SIM6-2 to check that the fan is actually rotating.
  • Code: L4-39
  • Description: Machine ventilation fan right lock
  • Causes: When the machine ventilation fan right is operated, the fan operation signal is not detected within the specified time.
  • Remedy: Case 1 Cause Fan connector disconnection Check and remedy Check the harness and the connector between the PCU PWB and the fan. Case 2 Cause Fan does not rotate because of other trouble. Check and remedy Use SIM6-2 to check that the fan is actually rotating.
  • Code: L4-40
  • Description: Ozone fan 1 lock
  • Causes: When the ozone fan 1 is operated, the fan operation signal is not detected within the specified time.
  • Remedy: Case 1 Cause Fan connector disconnection Check and remedy Check the harness and the connector between the PCU PWB and the fan. Case 2 Cause Fan does not rotate because of other trouble. Check and remedy Use SIM6-2 to check that the fan is actually rotating.
  • Code: L4-41
  • Description: Ozone fan 2 lock
  • Causes: When the ozone fan 2 is operated, the fan operation signal is not detected within the specified time.
  • Remedy: Case 1 Cause Fan connector disconnection Check and remedy Check the harness and the connector between the PCU PWB and the fan. Case 2 Cause Fan does not rotate because of other trouble. Check and remedy Use SIM6-2 to check that the fan is actually rotating.
  • Code: L4-42
  • Description: Ozone fan 3 lock
  • Causes: When the ozone fan 3 is operated, the fan operation signal is not detected within the specified time.
  • Remedy: Case 1 Cause Fan connector disconnection Check and remedy Check the harness and the connector between the PCU PWB and the fan. Case 2 Cause Fan does not rotate because of other trouble. Check and remedy Use SIM6-2 to check that the fan is actually rotating.
  • Code: L4-43
  • Description: Paper exit cooling fan center lock
  • Causes: When the paper exit cooling fan center is operated, the fan operation signal is not detected within the specified time.
  • Remedy: Case 1 Cause Fan connector disconnection Check and remedy Check the harness and the connector between the PCU PWB and the fan. Case 2 Cause Fan does not rotate because of other trouble. Check and remedy Use SIM6-2 to check that the fan is actually rotating.