Description: Improper combination of TEL/LIU PWB and FAX soft switch.
Causes: Incompatibility between the TEL/LIU PWB and the FAX control PWB information (soft switch)
Remedy: Case 1 Cause The destination of the TEL/LIU PWB installed is improper. Check and Remedy Check the destination of the TEL/LIU PWB. Case 2 Cause TEL/LIU PWB trouble. Check and Remedy Replace the TEL/LIU PWB.
Causes: FAX 1-chip microprocessor access error (Read and write)
Remedy: Case 1 Cause Program writing trouble to the 1-chip microprocessor, or no program data written. Check and Remedy Use SIM66-42 to rewrite the 1-chip microprocessor program. Case 2 Cause FAX 1-chip microprocessor circuit trouble. Check and Remedy Replace the FAX control PWB.
Description: Incompatibility between the FAX control PWB destination and the main machine destination. Incompatibility between the FAX control PWB destination and the main machine destination
Causes: Incompatibility between the destination information written into the FAX control PWB EEPROM and that in the main machine (set with SIM26-6)
Remedy: 1) Check the destination of the FAX control PWB. 2) Check the destination of the machine. (SIM26-6)
Causes: Thermistor trouble PCU PWB trouble Thermistor connector and harness connection trouble Fusing section connector connection trouble Fusing unit not installed
Remedy: Use SIM44-14 to check the state of the thermistor. Replace the thermistor. Replace the PCU PWB. Check connection of the thermistor connector and the harness. Check the connector in the fusing section.