Mã lỗi Sharp MX6580N — Trang 7/41
Description: Image data decode error (ACRE ASIC)
Causes: A decode error occurs while high compression PDF images are made. (garbled data) ACRE ASIC trouble. MFPC PWB trouble
Remedy: Check the MFPC PWB, and replace if necessary.
Description: Inconsistency between the MFP and the ACRE firmware
Causes: Written ACRE board of the firmware that a model did not support MFP was connected
Remedy: Check the kind and the version of the firmware. Use Sim49-1 or Sim49-10 to execute firmware version up
Description: ACRE ASIC memory error
Causes: ACRE ASIC trouble. MFPC PWB trouble
Remedy: Check the MFPC PWB, and replace if necessary.
Description: Water Mark data error
Causes: Watermark data trouble. HDD trouble.
Remedy: Use SIM49-5 to upload the watermark data. Replace the HDD.
Description: Combination error between PWB and firmware
Causes: A PWB/firmware/LSU which is not compatible with the machine specifications is detected. PCU PWB trouble LSU trouble
Remedy: Check the kind and the version of the firmware. Check or replace the LSU. Check or replace the PCU PWB.
Description: PWB information sum error
Causes: EEPROM device trouble. EEPROM device contact trouble. Device access error due to noises.
Remedy: Replace the PWB.
Description: Combination error between PWB and firmware
Causes: A PWB/firmware which is not compatible with the machine specifications is detected in the MFPC PWB. MFPC PWB trouble.
Remedy: Check the kind and the version of the firmware. Check or replace the MFPC PWB.
Description: Combination error between the MFPC PWB and the PCU PWB
Causes: Combination error between the MFPC PWB and the PCU PWB. MFPC PWB trouble. PCU PWB trouble.
Remedy: Check the combination between the MFPC PWB and the PCU PWB. Replace the MFPC PWB. Replace the PCU PWB.