Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Sharp MX7580N — Trang 9/41

Code: E7-96

Description: MFPC PWB DIMM memory check error. MFPC PWB DIMM memory access trouble
Causes: Memory data corruption occurs MFPC PWB trouble DIMM memory trouble or contact error
Remedy: Use SIM60-01 to check the read/write operations of the memory. Replace the MFPC PWB. DIMM memory socket check Replace the DIMM memory.

Code: E7-A0

Description: LSU EEPROM/LD driver read/write error (K). Write error in write sequence of the serial EEPROM/ LD driver for Black
Causes: EEPROM/LD driver trouble. EEPROM/LD driver access circuit trouble
Remedy: Check connection of the connector and the harness of the LD PWB and the PCU PWB. Replace the PCU PWB. If the above remedies cannot delete the trouble, replace the LSU.

Code: E7-A1

Description: LSU EEPROM/LD driver read/write error (C). Write error in write sequence of the serial EEPROM/ LD driver for Cyan
Causes: EEPROM/LD driver trouble. EEPROM/LD driver access circuit trouble
Remedy: Check connection of the connector and the harness of the LD PWB and the PCU PWB. Replace the PCU PWB. If the above remedies cannot delete the trouble, replace the LSU.

Code: E7-A2

Description: LSU EEPROM/LD driver read/write error (M). Write error in write sequence of the serial EEPROM/ LD driver for Magenta
Causes: EEPROM/LD driver trouble. EEPROM/LD driver access circuit trouble
Remedy: Check connection of the connector and the harness of the LD PWB and the PCU PWB. Replace the PCU PWB. If the above remedies cannot delete the trouble, replace the LSU.

Code: E7-A3

Description: LSU EEPROM/LD driver read/write error (Y). Write error in write sequence of the serial EEPROM/ LD driver for Yellow
Causes: EEPROM/LD driver trouble. EEPROM/LD driver access circuit trouble
Remedy: Check connection of the connector and the harness of the LD PWB and the PCU PWB. Replace the PCU PWB. If the above remedies cannot delete the trouble, replace the LSU.

Code: E7-A7

Description: SSD trouble
Causes: SSD trouble Improper connection of SSD MFP PWB trouble Data error of the file system management part
Remedy: Remove and insert the SSD Replace the SSD Replace the MFP PWB

Code: E7-C0

Description: TPM PWB data access error
Causes: TPM PWB error, poor connection Installed TPM PWB used with other MFP
Remedy: Turn power off and on Check and confirm TPM PWB insertion

Code: E7-C1

Description: Security check error
Causes: TPM PWB error Program error Security function, setting error
Remedy: Turn power off and on Check and confirm TPM PWB insertion