Mã lỗi Sharp MXB380P — Trang 9/18

Code: F2-41

Description: Toner density sensor trouble (CYAN)
Causes: Toner density sensor output abnormality (Sample level 25 or less, or 231 or above) Connection trouble of the connector and the harness. Developing unit trouble. PCU PWB trouble
Remedy: Replace the toner density sensor. Harness and connector connection trouble. Replace the developing unit. Replace the PCU PWB.

Code: F2-42

Description: Toner density sensor trouble (MAGENTA)
Causes: Toner density sensor output abnormality (Sample level 25 or less, or 231 or above) Connection trouble of the connector and the harness. Developing unit trouble. PCU PWB trouble
Remedy: Replace the toner density sensor. Harness and connector connection trouble. Replace the developing unit. Replace the PCU PWB.

Code: F2-43

Description: Toner density sensor trouble (YELLOW)
Causes: Toner density sensor output abnormality (Sample level 25 or less, or 231 or above). Connection trouble of the connector and the harness. Developing unit trouble. PCU PWB trouble.
Remedy: Replace the toner density sensor. Harness and connector connection trouble. Replace the developing unit. Replace the PCU PWB.

Code: F2-45

Description: K image density sensor trouble
Causes: K image density sensor sensitivity adjustment trouble. K image density sensor trouble. Harness and connector connection trouble. K image density sensor dirt. Calibration plate dirt. Calibration plate solenoid trouble. PCU PWB trouble.
Remedy: Replace the K image density sensor. Check connection of the connectors and the harness. Clean the K image density sensor. Replace the calibration plate. Replace the calibration plate solenoid. Replace the PCU PWB. Use SIM44-2 to adjust the process control sensor sensitivity.

Code: F2-49

Description: LSU thermistor trouble
Causes: The LSU detection temperature is outside of -28..C - 78..C. LSU thermistor trouble. Harness and connector connection trouble. PCU PWB trouble LSU control PWB trouble.
Remedy: Replace the LSU thermistor. Check connection of the connectors and the harness. Replace the PCU PWB. Replace the LSU control PWB. Replace the LSU.

Code: F2-50

Description: K drum phase sensor trouble
Causes: Drum phase sensor trouble. Harness and connector connection trouble. Drum drive section trouble. PCU PWB trouble
Remedy: Use SIM30-1 to check the operation of "DHPD_K.". Replace the drum phase sensor. Check connection of the connectors and the harness. Repair the drum drive section. Replace the PCU PWB.

Code: F2-51

Description: CL drum phase sensor trouble
Causes: Drum phase sensor trouble. (DHPCL) Harness and connector connection trouble. Drum drive section trouble. PCU PWB trouble.
Remedy: Use SIM30-1 to check the operation of "DHPD_CL". Replace the drum phase sensor. Check connection of the connectors and the harness. Repair the drum drive section. Replace the PCU PWB.

Code: F2-58

Description: Process humidity sensor trouble
Causes: Process humidity sensor trouble. Harness and connector connection trouble. PCU PWB trouble.
Remedy: Replace the process humidity sensor. Check connection of the connectors and the harness. Replace the PCU PWB.