Description: Registration image density sensor trouble (Transfer belt substrate reflection rate abnormality)
Causes: Image density (registration) sensor trouble (Sensor sensitivity adjustment trouble). PCU PWB trouble. Connection trouble of the connector and the harness. Image density (registration) sensor dirt. Transfer belt dirt, scratch.
Remedy: Replace the image density (registration) sensor. Replace the PCU PWB. Harness and connector connection trouble. Clean the image density (registration) sensor. Clean or replace the transfer belt.
Description: Paper feed tray 1 lift operation trouble
Causes: LUD1 is not turned ON within the specified time. CLUD1 sensor trouble Paper feed tray 1 lift unit trouble. PCU PWB trouble. Harness and connector connection trouble.
Remedy: Check connection of the harness and the connector of LUD1. Replace the lift-up unit. Replace the PCU PWB.