Code: E7-62

Description: Controller connection trouble (scanner)
Controller connection trouble. Compatibility trouble between the controller and the scanner.
Causes: Combination error between the controller PWB and the engine.
Remedy: Check the controller PWB. Check combination between the controller PWB and the scanner.

Code: E7-65

Description: MFP EEPROM sum check error
EEPROM PWB information sum error
Causes: EEPROM device trouble. EEPROM device contact trouble. Device access error due to noises.
Remedy: Replace the PWB.

Code: E7-70

Description: Scanner connection trouble
Unknown PWB identification information is detected on the SCU PWB
Causes: The PWB / firmware which is not supported by the machine specifications is connected. SCU PWB trouble. DSPF PWB trouble.
Remedy: Check the firmware kind and the version. Check the SCU PWB. Check the DSPF PWB.

Code: E7-71

Description: DSPF connection trouble
An unknown PWB identification information is detected in the DSPF PWB/ combination abnormality with the SCU PWB
Causes: PWB / firmware which does not support the machine specifications is connected.
Remedy: Firmware kind / Version check.

Code: E7-75

Description: DSPF connection trouble
An unknown PWB identification information is detected in the DSPF PWB/ combination abnormality with the SCU PWB
Causes: PWB / firmware which does not support the machine specifications is connected.
Remedy: Firmware kind / Version check.

Code: E7-75

Description: PWB information sum error (scanner detection)
EEPROM PWB information sum error
Causes: EEPROM device trouble. EEPROM device contact trouble. Device access error due to noises.
Remedy: Replace the SCU PWB.

Code: E7-76

Description: PWB information sum error (DSPF detection)
FLASH ROM PWB information sum error
Causes: FLASH ROM device trouble. FLASH ROM device contact trouble. Device access error due to noises.
Remedy: Replace the DSPF PWB.

Code: E7-80

Description: MFP - SCU PWB communication error
Causes: SCU PWB - MFPC PWB connection trouble. SCU PWB trouble. MFPC PWB trouble.
Remedy: Check connection of the SCU PWB and the MFPC PWB. Check the ground. Replace the SCU PWB. Replace the MFPC PWB.
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie