Các lỗi thường gặp

Code :
  • Code: L8-10
  • Description: Power abnormality detection trouble
    The power status monitoring signal keeps power OFF state after passing the specified time (2sec).
  • Causes: Circuit around the power status monitoring signal (PSSTS) failure.
  • Remedy: Check whether power status monitoring signal (PSSTS) on MCU PWB is OPEN or not. Replace MCU PWB.
  • Code: PF-00
  • Description: PF trouble
    The copy inhibit command from RIC is received.
  • Causes: Judged by the host.
  • Remedy: Inform to the host.
  • Code: U1-01
  • Description: FAX battery error
    The SRAM backup battery voltage on FAX control PWB falls.
  • Causes: The SRAM backup battery voltage on FAX control PWB falls.
  • Remedy: Check voltage of the SRAM back up battery. Replace the battery.
  • Code: U1-02
  • Description: PANEL LOW battery error
    The voltage of the panel clock function battery falls.
  • Causes: The voltage of the panel clock function battery falls.
  • Remedy: Check voltage of panel clock function battery. Replace the battery.
  • Code: U2-04
  • Description: EEPROM communication error
    EEPROM communication error
  • Causes: EEPROM defect. ICU PWB EEPROM access circuit failure.
  • Remedy: Check that the EEPROM is properly set. Clear trouble with SIM 16. Replace the MCU PWB.
  • Code: U2-20
  • Description: Machine speed code data error
    The machine boot speed information is not identical to the model code speed information
  • Causes: EEPROM defect. SIM operation error.
  • Remedy: Check for matching of the machine and model information setting in SIM26-57.
  • Code: U7-00
  • Description: RIC communication trouble
    Error in communication with RIC. Error in communication test after turning on the power or canceling SIM.
  • Causes: Connector harness contact trouble or disconnection. RIC control PWB trouble. MCU PWB failure. Malfunction by noises.
  • Remedy: Check the communication cable, connectors from the RIC box to the main body.
  • Code: U9-00
  • Description: Operation control PWB communication trouble
    Communication trouble between MCU and the operation control PWB
  • Causes: Operation control PWB connector disconnection Harness failure of the operation control PWB and the MCU PWB
  • Remedy: Check the connectors and the harness of the operation control PWB and MCU PWB. Check the grounding of the copier. Check ROM on the operation control PWB.