Description: Conflict firmware and EEPROM data version (PCU)
Causes: Inconsistency between the PCU firmware version and the EEPROM data version.
Remedy: Check the combination of the firmware.
Code: A0-22
Description: Conflict firmware and EEPROM data version (SCU)
Causes: Inconsistency between the SCU firmware version and the EEPROM data version.
Remedy: Check the combination of the firmware.
Code: C1-10
Description: Main charger trouble
Causes: The main charger unit is not installed properly. There is an abnormality in the main charger unit. Disconnection of the high voltage PWB connector. MC/DV high voltage PWB trouble. PCU PWB trouble
Remedy: Check the output of the main charger with SIM8-2. Check disconnection of the main charger./Replace. Check disconnection of the high voltage PWB connector./Replace. Replace the MC/DV high voltage PWB. Replace the PCU PWB.
Causes: Installation error of the CCD unit harness. Copy lamp lighting trouble. Dirt on the reference white plate. CCD unit trouble. DSPF PWB trouble. Shading adjustment error
Remedy: Check the installing state of the harness the CCD unit. Clean the reference white plate. Check the CCD unit. Check the DSPF PWB.
Code: E6-14
Description: CCD-ASIC error
Causes: DSPF PWB trouble
Remedy: Replace the DSPF PWB.
Code: E7-01
Description: MFP image data error
Causes: Image data transfer error in the MFP PWB. MFP PWB trouble.
Remedy: Check connection of the connector and the harness of the MFP PWB. Replace the MFP PWB.
Code: E7-03
Description: HDD trouble
Causes: Connector, harness connection trouble in the MFP PWB and HDD. HDD error file management area data abnormality (FAT breakage). MFP PWB trouble.
Remedy: Check connection of the connector and the harness of the MFP PWB and HDD. Use SIM62-2,3 to check read/write operations of the HDD. Replace the HDD. Replace the MFP PWB.