Các lỗi thường gặp

Code :
  • Code: H7-10
  • Description: Recovery error from low fuser temperature
  • Causes: Thermistor trouble. Heater lamp trouble. PCU PWB trouble. Thermostat trouble. Connector, harness connection trouble. HL control PWB trouble. Power unit trouble.
  • Remedy: Replace the thermistor. Replace the heater lamp. Replace the PCU PWB. Replace the thermostat. Check connection of the connector and the harness. Replace the HL control PWB. Replace the power unit. Use SIM5-2 to check the flashing operation of the heater lamp.
  • Code: H7-12
  • Description: Recovery error from low fuser temp (TH_US)
  • Causes: Thermistor trouble. Heater lamp trouble. PCU PWB trouble. Thermostat trouble. Connector, harness connection trouble. HL control PWB trouble. Power unit trouble.
  • Remedy: Replace the thermistor. Replace the heater lamp. Replace the PCU PWB. Replace the thermostat. Check connection of the connector and the harness. Replace the HL control PWB. Replace the power unit. Use SIM5-2 to check the flashing operation of the heater lamp.
  • Code: L1-00
  • Description: Scanner feed trouble
  • Causes: Scanner unit trouble. SCU PWB trouble. Scanner control PWB trouble. Harness and connector connection trouble. Scanner home position sensor trouble. Scanner motor trouble.
  • Remedy: Use SIM1-1 to check the scan operation. Replace the scanner unit. Replace the SCU PWB. Check connection of the connectors and the harness. Replace the scanner home position sensor. Replace the scanner motor.
  • Code: L3-00
  • Description: Scanner return trouble
  • Causes: Scanner unit trouble SCU PWB trouble Scanner control PWB trouble Harness and connector connection trouble Scanner home position sensor trouble Scanner motor trouble
  • Remedy: Use SIM1-1 to check the scan operation. Replace the scanner unit. Replace the SCU PWB. Check connection of the connectors and the harness. Replace the scanner home position sensor. Replace the scanner motor.
  • Code: L4-02
  • Description: Paper feed motor trouble
  • Causes: Paper feed motor trouble Paper feed motor harness and connector connection trouble PCU PWB trouble
  • Remedy: Use SIM6-1 to check the operation of the paper feed motor. Replace the paper feed motor. Check connection of the paper feed motor harness and the connector. Replace the PCU PWB.
  • Code: L4-03
  • Description: Fusing motor trouble
  • Causes: Fusing motor trouble Fusing motor harness and connector connection trouble PCU PWB trouble
  • Remedy: Use SIM6-1 to check the operation of the fusing motor. Replace the Fusing motor. Check connection of the fusing motor harness and the connection. Replace the PCU PWB.
  • Code: L4-06
  • Description: Transfer unit pressure welding or estrangement trouble
  • Causes: Transfer unit position sensor trouble Dirt on the transfer unit position sensor. PCU PWB trouble Connection trouble of the connector and the harness. Transfer unit lift mechanism trouble Transfer unit attachment trouble.
  • Remedy: Use SIM6-3 to check the estrangement operation of the transfer unit. Replace the transfer unit position sensor. Clean the transfer unit position sensor. Replace the PCU PWB. Check connection of the connector and the harness. Repair the transfer unit lift mechanism.
  • Code: L4-08
  • Description: Waste toner transport motor lock
  • Causes: Waste toner transport motor trouble. Waste toner transport pipe clogging Harness/connector trouble between the PCU PWB and the waste toner transport motor.
  • Remedy: Use SIM6-1 to check the operation of the waste toner transport motor (WTM). Check the waste toner transport pipe for clogging. Check the harness and the connector between the PCU PWB and the waste toner transport motor.