Description: Process cooling fan 2 trouble. The lock signal is detected during operation of the process cooling fan
Causes: Harness connection trouble between the PCU PWB and the fan motor. PCU PWB trouble. Fan motor trouble. The fan is not rotating due to other trouble. (Power is not supplied to the fan motor.)
Remedy: Use Sim. 6-2 to check the operation of the fan motor. Check the harness and the connector between the PCU PWB and the fan motor. Replace the PCU PWB. Replace the fan motor.
Description: Process cooling fan 3 trouble. The lock signal is detected during operation of the process cooling fan
Causes: Harness connection trouble between the PCU PWB and the fan motor. PCU PWB trouble. Fan motor trouble. The fan is not rotating due to other trouble. (Power is not supplied to the fan motor.)
Remedy: Use Sim. 6-2 to check the operation of the fan motor. Check the harness and the connector between the PCU PWB and the fan motor. Replace the PCU PWB. Replace the fan motor.
Description: Process cooling fan 4 trouble. The lock signal is detected during operation of the process cooling fan
Causes: Harness connection trouble between the PCU PWB and the fan motor. PCU PWB trouble. Fan motor trouble. The fan is not rotating due to other trouble. (Power is not supplied to the fan motor.)
Remedy: Use Sim. 6-2 to check the operation of the fan motor. Check the harness and the connector between the PCU PWB and the fan motor. Replace the PCU PWB. Replace the fan motor.
Description: PS cooling fan trouble. The lock signal is detected during operation of the PS cooling fan
Causes: Harness connection trouble between the PCU PWB and the fan motor. PCU PWB trouble. Fan motor trouble. The fan is not rotating due to other trouble. (Power is not supplied to the fan motor.)
Remedy: Use Sim. 6-2 to check the operation of the fan motor. Check the harness and the connector between the PCU PWB and the fan motor. Replace the PCU PWB. Replace the fan motor.
Description: Process cooling fan trouble. The lock signal is detected during operation of the process cooling fan
Causes: Harness connection trouble between the PCU PWB and the fan motor. PCU PWB trouble. Fan motor trouble. The fan is not rotating due to other trouble. (Power is not supplied to the fan motor.)
Remedy: Use Sim. 6-2 to check the operation of the fan motor. Check the harness and the connector between the PCU PWB and the fan motor. Replace the PCU PWB. Replace the fan motor.
Description: Polygon motor trouble. It is judged that the lock signal of the LSU polygon motor is not outputted. When the lock signal is checked 7sec after starting the polygon motor rotation, it is judged that the polygon motor does not rotate normally.
Causes: Disconnection or breakage of the LSU connector or the harness inside the LSU. Polygon motor trouble. LSU PWB trouble.
Remedy: Check the polygon motor operation with Sim. 61-1. Check connection of the harness and the connector. If the trouble still remains, replace the LSUcnt PWB or replace the LSU PWB.