Description: Production number data discrepancy (ICU-PCU). The production number saved in the PCU differs from that saved in the ICU
Causes: When replacing the PCU/ ICU PWB, the EEPROM is not changed.
Remedy: Check that the EEPROM is properly set. When replacing the PWB, check that the EEPROM before replacement is inserted to the PWB after replacement.
Description: HD section individual data check sum error (MFP). W-ICU PWB HD individual data check sum error. (One touch, group, program, etc.)
Causes: Read /write trouble from/ to HD. Control circuit malfunction due to line noise. W-ICU PWB HD access circuit trouble.
Remedy: Turn OFF / ON the power to initialize the data related to the content of check sum error. Since the registered content is deleted, register the deleted content again. Use Sim. 16 to cancel the U2 trouble. Replace the HD. Replace the MFPC, W-ICU PWB.
Remedy: Check that the EEPROM is properly set. To keep the counter data and the adjustment values, use the simulation to save the counter data and the adjustment values. (When there is a printer option, execute Sim.22-1 to save the counter data and the adjustment values.) Replace the SCU PWB. Use Sim. 16 to cancel the trouble.
Description: EEPROM check sum error (SCU detection)
Causes: EEPROM trouble. Control circuit malfunction due to line noise. SCU PWB EEPROM access circuit trouble.
Remedy: Check that the EEPROM is properly set. To keep the counter data and the adjustment values, use the simulation to save the counter data and the adjustment values. (When there is a printer option, execute Sim. 22-1 to save the counter data and the adjustment values.) Replace the SCN PWB. Use Sim. 16 to cancel the trouble.
Remedy: Check that the EEPROM is properly set. To keep the counter data and the adjustment values, use the simulation to save the counter data and the adjustment values. (When there is a printer option, execute Sim. 22-1 to save the counter data and the adjustment values.) Replace the PCU PWB. Use Sim. 16 to cancel the trouble.
Description: EEPROM check sum error (PCU detection)
Causes: EEPROM trouble. Control circuit malfunction due to noises. PCU PWB EEPROM access circuit trouble.
Remedy: Check that the EEPROM is properly set. To keep the counter data and the adjustment values, use the simulation to save the counter data and the adjustment values. (When there is a printer option, execute Sim. 22-1 to save the counter data and the adjustment values.) Replace the PCU PWB. Use Sim. 16 to cancel the trouble.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.