Description: PFP side cover open jam: The PFP side cover has opened during printing.
Remedy: Is the PFP side cover open? YES Remove the paper if there is any, then close the cover. NO Is the PFP side cover opening/closing switch working? (Perform the input check in the test mode: 03-[FAX]OFF/[2]/[A]) NO 1. Check if the connector of the PFP side cover opening/closing switch is disconnected. 2. Check if either of the connectors CN241 or CN243 on the PFP board is disconnected. 3. Check if the connector CN318 on the LGC board is disconnected. 4. Check if the connector pins are disconnected and the harnesses are open circuited. 5. Check if the conductor patterns on the PFP board and LGC board are short circuited or open circuited. 6. Replace the PFP side cover opening/closing switch. 7. Replace the PFP board. 8. Replace the LGC board. YES 1. Replace the PFP board. 2. Replace the LGC board.
Code: E430
Description: ADU open jam: The ADU has opened during printing
Remedy: Is the ADU open? YES Remove the paper if there is any, then close the ADU. NO Is the ADU opening/closing switch working? (Perform the input check in the test mode: 03-[FAX]ON/[9]/[F]) NO 1. Check if the connector of the ADU opening/closing switch is disconnected. 2. Check if the connector CN311 on the LGC board is disconnected. 3. Check if the connector pins are disconnected and the harnesses are open circuited. 4. Check if the conductor patterns on the LGC board are short circuited or open circuited. 5. Replace the ADU opening/closing switch. 6. Replace the LGC board. YES 1. Replace the LGC board.
Code: E440
Description: Feed cover open jam: The feed cover has opened during printing.
Remedy: Is the feed cover open? YES Remove the paper if there is any, then close the cover. NO Is the feed cover opening/closing detection sensor working? (Perform the input check in the test mode: 03-[FAX]ON/[9]/[E]) NO 1. Check if the connector of the feed cover opening/closing detection sensor is disconnected. 2. Check if the connector CN311 on the LGC board is disconnected. 3. Check if the connector pins are disconnected and the harnesses are open circuited. 4. Check if the conductor pattern on the LGC board is short circuited or open circuited. 5. Replace the feed cover opening/closing detection sensor. 6. Replace the LGC board. YES Replace the LGC board.
Code: E450
Description: LCF side cover open jam: The LCF side cover has opened during printing.
Remedy: Is the LCF side cover open? YES Remove the paper if there is any, then close the cover. NO Is the LCF side cover opening/closing switch working? (Perform the input check in the test mode: 03-[FAX]OFF/[4]/[B]) NO 1. Check if the connector of the LCF side cover opening/closing switch is disconnected. 2. Check if either of the connectors CN1 or CN7 on the LCF board is disconnected. 3. Check if the connector CN318 on the LGC board is disconnected. 4. Check if the connector pins are disconnected and the harnesses are open circuited. 5. Check if the conductor patterns on the LCF board and LGC board are short circuited or open circuited. 6. Replace the LCF side cover opening/closing switch. 7. Replace the LCF board. 8. Replace the LGC board. YES 1. Replace the LCF board. 2. Replace the LGC board.
Code: E480
Description: Bridge unit open jam: The bridge unit has opened during printing.
Remedy: Is the bridge unit open? YES Remove the paper if there is any, then close the unit. NO Is the bridge unit opening/closing switch working? (Perform the input check in the test mode: 03-[FAX]ON/[3]/[E] / 03-[FAX]ON/[4]/[E]) NO 1. Check if the connector of the bridge unit opening/closing switch is disconnected. 2. Check if the connector CN302 / CN400 on the LGC board is disconnected. 3. Check if the connector pins are disconnected and the harnesses are open circuited. 4. Check if the conductor pattern on the LGC board is short circuited or open circuited. 5. Replace the bridge unit opening/closing switch. 6. Replace the LGC board. YES Replace the LGC board.
Code: E490
Description: Job separator cover open jam: The job separator cover has opened during printing.
Remedy: Is the JSP cover open? YES Remove the paper if there is any, then close the cover. NO Is the JSP cover switch working? (Perform the input check in the test mode: 03-[FAX]ON/[3]/[E]) NO 1. Check if the connector of the JSP cover switch is disconnected. 2. Check if either of the connectors CN260 or CN261 on the JSP board is disconnected. 3. Check if the connector CN302 on the LGC board is disconnected. 4. Check if the connector pins are disconnected and the harnesses are open circuited. 5. Check if the conductor patterns on the JSP board and LGC board are short circuited or open circuited. 6. Replace the JSP cover switch. 7. Replace the JSP board. 8. Replace the LGC board. YES 1. Replace the JSP board. 2. Replace the LGC board.
Code: E491
Description: Offset tray cover open jam: The offset tray cover has opened during printing.
Remedy: Is the OCT cover open? YES Remove the paper if there is any, then close the cover. NO Is the OCT cover switch working? (Perform the input check in the test mode: 03-[FAX]ON/[3]/[E]) NO 1. Check if the connector of the OCT cover switch is disconnected? 2. Check if either of the connectors CN260 or CN261 on the OCT board is disconnected. 3. Check if the connector CN302 on the OCT board is disconnected. 4. Check if the connector pins are disconnected and the harnesses are open circuited. 5. Check if the conductor patterns on the OCT board and LGC board are short circuited or open circuited. 6. Replace the OCT cover switch. 7. Replace the OCT board. 8. Replace the LGC board. YES 1. Replace the OCT board. 2. Replace the LGC board.
Code: E510
Description: Jam not reaching the ADU entrance sensor: The paper does not reach the ADU entrance sensor after it is switchbacked in the exit section.
Remedy: Open the ADU. Is there any paper in front of the ADU exit sensor? YES Remove the paper. NO Is the ADU exit sensor working? (Perform the input check in the test mode: 03-[FAX]OFF/[1]/[E]) NO 1. Check if the connector of the ADU exit sensor is disconnected. 2. Check if the connector CN311 on the LGC board is disconnected. 3. Check if the connector pins are disconnected and the harnesses are open circuited. 4. Check if the conductor patterns on the LGC board are short circuited or open circuited. 5. Replace the ADU exit sensor. 6. Replace the LGC board. YES Is the ADU motor working? (Perform the output check in the test mode: 03-119) NO 1. Check if the connector of the ADU motor is disconnected. 2. Check if the connector CN402 and CN404 on the MOT/MOT2 board is disconnected. 3. Check if the connector CN303 on the LGC board is disconnected. 4. Check if the connector pins are disconnected and the harnesses are open circuited. 5. Check if the conductor pattern on the LGC board is short circuited or open circuited. 6. Replace the ADU exit sensor. 7. Replace the MOT/MOT2 board. 8. Replace the LGC board. YES Check the rollers in the ADU. Replace them if they are worn out