Các lỗi thường gặp

Code :
  • Code: C570
  • Description: Communication error between Engine-CPU and IPC board
  • Causes: LGC board IPC board
  • Remedy: LGC board • Check if the LGC board and IPC board are connected properly. • Check if the conductor pattern on the LGC board is short circuited or open circuited. IPC board Check if the conductor pattern on the IPC board is short circuited or open circuited.
  • Code: C580
  • Description: Communication error between IPC board and finisher
  • Causes: IPC board Finisher controller PC board
  • Remedy: Finisher Check if the specified finisher is attached. IPC board • Check if the harness connecting the IPC board and the finisher controller PC board is disconnected or open circuited. • Check if the conductor pattern on the IPC board is short circuited or open circuited. Finisher controller PC board Check if the conductor pattern on the finisher controller PC board is short circuited or open circuited.
  • Code: C5A0
  • Description: SRAM board not connected (LGC board)
  • Causes: SRAM board LGC board
  • Remedy: bSRAMoard • Connector check (CN170) • Board check LGC board • Connector check (CN363) • Board check
  • Code: C5A1
  • Description: SRAM board data abnormality (LGC board)
  • Causes: SRAM board LGC board
  • Remedy: SRAM board • Connector check (CN170) • Board check LGC board • Connector check (CN363) • Board check
  • Code: C8E0
  • Description: RADF communication protocol abnormality: The system has to be stopped because the control
  • Causes: RADF board
  • Remedy: Power Turn the power OFF and then back ON to check if the equipment operates normally. RADF board • Connector check • Board check
  • Code: C900
  • Description: Connection error between SYS board and LGC board
  • Causes: LGC board IMG board SYS board
  • Remedy: LGC board • Connector check (CN354) • Board check IMG board • Connector check (CN422, CN423) • Board check SYS board • Connector check (CN135) • Board check
  • Code: C901
  • Description: System format error for scanner
  • Causes: LGC board IMG board SYS board
  • Remedy: Main power switch Does service call still occur even after turning OFF the main power switch then back ON? SLG board • Connector check (CN12) • Board check SYS board • Connector check (CN135) • Board check
  • Code: C910
  • Description: Toner cartridge IC chip access board abnormality
  • Causes: Toner cartridge LGC board HRNS-LGC-TNRIC-140 CTIF board HRNS-TNRIC-140
  • Remedy: 1 Does the non-genuine toner cartridge display appear when the front cover is opened and closed? Yes Use the genuine toner cartridge. 2 No 2 2 Toner cartridge • Check the phenomenon by removing the toner cartridges (Y, M, C and K) and reinserting them. • Check that the CTRG board of each cartridge (Y, M, C and K) is installed properly. 3 Contact point on the equipment side Check that the spring of the contact point for each color (Y, M, C and K) is not deformed. 4 Is the spring of the contact point returned when it is pushed lightly? Yes No • Check that the CTIF board is installed properly. • Board check 7 Notes: The spring of the contact point may be released if you push the toner cartridge all the way in when an abnormality occurs. 5 LGC board • Connector check (CN364) • Board check 6 HRNS-LGC-TNRIC-140 • Relay connector check (J556, J557, J558, J559) • Harness check 7 CTIF board for each color (Y, M, C and K) • Check that the board is installed properly. • Board check 8 HRNS-TNRIC-140 for each color (Y, M, C and K) • Connector check • Harness check