Description: Pressure roller thermistor abnormality after entering ready status (pre-running end temperature abnormality)
Causes: Power supply unit LGC board
Remedy: Pressure roller thermistor • Connector check • Check if the pressure roller center/rear thermistor is installed properly. • Check if the harnesses of the pressure roller center and rear thermistors are open circuited. Power supply unit and fuser unit • Check if the fuser unit is installed properly. • Check if the pressure roller lamp is open circuited. (Check if the pressure roller lamp has electric continuity.) • Check if the connector of the pressure roller lamp is disconnected. • Check if the thermistor is open circuited. • Check if the connectors of the power supply (CN404, CN405, CN408, CN409) are disconnected. • Check if the power supply unit is broken. LGC board • Connector check (CN333, CN345, CN361) • Check if the conductor pattern on the board is short circuited or open circuited. Status counter Change the current status counter value (08-2002) "5", "6", "8", "18", "20", "26", "28", "33" or "34" to "0" • The status counter value is set as follows in the following cases. • The error occurred during warming-up: "5" or "6" • The error occurred after the equipment has become ready: "33" • Regardless of the equipment’s status (i.e. during warmingup, printing, paper jam or in ready status), when the temperature detected by the pressure roller thermistor is 210°C or higher: "8", "18", "20", "26" or "28". • The error occurred during printing: "34"
Code: C466
Description: Pressure roller thermistor abnormality after entering ready status (pre-running end temperature abnormality)
Causes: Power supply unit LGC board
Remedy: Pressure roller thermistor • Connector check • Check if the pressure roller center/rear thermistor is installed properly. • Check if the harnesses of the pressure roller center and rear thermistors are open circuited. Power supply unit and fuser unit • Check if the fuser unit is installed properly. • Check if the pressure roller lamp is open circuited. (Check if the pressure roller lamp has electric continuity.) • Check if the connector of the pressure roller lamp is disconnected. • Check if the thermistor is open circuited. • Check if the connectors of the power supply (CN404, CN405, CN408, CN409) are disconnected. • Check if the power supply unit is broken. LGC board • Connector check (CN333, CN345, CN361) • Check if the conductor pattern on the board is short circuited or open circuited. Status counter Change the current status counter value (08-2002) "5", "6", "8", "18", "20", "26", "28", "33" or "34" to "0" • The status counter value is set as follows in the following cases. • The error occurred during warming-up: "5" or "6" • The error occurred after the equipment has become ready: "33" • Regardless of the equipment’s status (i.e. during warmingup, printing, paper jam or in ready status), when the temperature detected by the pressure roller thermistor is 210°C or higher: "8", "18", "20", "26" or "28". • The error occurred during printing: "34"
Code: C467
Description: Pressure roller thermistor abnormality after entering ready status (temperature abnormality at ready status)
Causes: Power supply unit LGC board
Remedy: Pressure roller thermistor • Connector check • Check if the pressure roller center/rear thermistor is installed properly. • Check if the harnesses of the pressure roller center and rear thermistors are open circuited. Power supply unit and fuser unit • Check if the fuser unit is installed properly. • Check if the pressure roller lamp is open circuited. (Check if the pressure roller lamp has electric continuity.) • Check if the connector of the pressure roller lamp is disconnected. • Check if the thermistor is open circuited. • Check if the connectors of the power supply (CN404, CN405, CN408, CN409) are disconnected. • Check if the power supply unit is broken. LGC board • Connector check (CN333, CN345, CN361) • Check if the conductor pattern on the board is short circuited or open circuited. Status counter Change the current status counter value (08-2002) "5", "6", "8", "18", "20", "26", "28", "33" or "34" to "0" • The status counter value is set as follows in the following cases. • The error occurred during warming-up: "5" or "6" • The error occurred after the equipment has become ready: "33" • Regardless of the equipment’s status (i.e. during warmingup, printing, paper jam or in ready status), when the temperature detected by the pressure roller thermistor is 210°C or higher: "8", "18", "20", "26" or "28". • The error occurred during printing: "34"
Code: C468
Description: Pressure roller thermistor abnormality after entering ready status (overheating)
Causes: Power supply unit LGC board
Remedy: Pressure roller thermistor • Connector check • Check if the pressure roller center/rear thermistor is installed properly. • Check if the harnesses of the pressure roller center and rear thermistors are open circuited. Power supply unit and fuser unit • Check if the fuser unit is installed properly. • Check if the pressure roller lamp is open circuited. (Check if the pressure roller lamp has electric continuity.) • Check if the connector of the pressure roller lamp is disconnected. • Check if the thermistor is open circuited. • Check if the connectors of the power supply (CN404, CN405, CN408, CN409) are disconnected. • Check if the power supply unit is broken. LGC board • Connector check (CN333, CN345, CN361) • Check if the conductor pattern on the board is short circuited or open circuited. Status counter Change the current status counter value (08-2002) "5", "6", "8", "18", "20", "26", "28", "33" or "34" to "0" • The status counter value is set as follows in the following cases. • The error occurred during warming-up: "5" or "6" • The error occurred after the equipment has become ready: "33" • Regardless of the equipment’s status (i.e. during warmingup, printing, paper jam or in ready status), when the temperature detected by the pressure roller thermistor is 210°C or higher: "8", "18", "20", "26" or "28". • The error occurred during printing: "34"
Code: C4B0
Description: Fuser unit counter abnormality
Causes: LGC board
Remedy: LGC board • Check if the conductor pattern on the board is short circuited or open circuited. • Check if SRAM is mounted. Status counter Change the values “52“ or above, “4“, "10", "11", "12", "13", "14", "15", "16", "17", "35", "36", "37", "40", "43", "44", "45", "46" or "47" of the status counter (08-2002) to “0“.
Code: C4B1
Description: Fuser unit destination selection abnormality
Causes: LGC board
Remedy: Fuser unit • Check if the fuser unit is installed correctly or if its destination is correct. • Check if any harness in the fuser unit is caught. LGC board • Check if the destination of the SRAM is correct.
Code: C4D0
Description: Fuser belt thermopile abnormality
Causes: Thermopile LGC board
Remedy: Thermopile • Connector check • Check if the harnesses of the fuser belt center thermopile and the fuser belt side thermopile are open circuited. LGC board • Connector check (CN333) • Check if the conductor pattern on the LGC board is open circuited or short circuited. Cancel the service call After repairing the matter which caused the error [C4D0], turn the power OFF and then back ON to cancel the service call. However, the counter value will be stored until it is written over by the value of the other service call.
Code: C550
Description: RADF I/F error: Communication error has occurred between the RADF and the scanner.
Causes: RADF board SLG board
Remedy: RADF board • Check if the harness connecting the RADF board and SLG board is disconnected or open circuited. • Check if the conductor pattern on the RADF board is short circuited or open circuited. SLG board Check if the conductor pattern on the SLG board is short circuited or open circuited.