Code: C4E2

Description: Fuser belt rotation detection sensor abnormality. The fuser belt does not rotate or does so incorrectly/the abnormality of the sensor of the fuser unit (front/color of harness: yellow)
Causes: Fuser belt rotation detection sensor Detection plate (rotor) Dirty/damaged Fuser belt Deformed/damaged Bushing of fuser belt drive shaft Worn Bushing of fuser drive unit Worn Drive plate Bend section broken Gear Teeth damaged, worn LGC board Fuser motor
Remedy: Fuser unit • Fuser belt rotation detection sensor check (Input check: 03-[ALL]OFF/[6]/[A]) • Connector check in the fuser belt rotation sensor • Harness check in the fuser belt rotation sensor • Rotation detection plate (rotor) check • Grease check in the gear (shaft / tooth flank) • Fuser belt check • Check if the bushing of fuser belt drive shaft is worn. • Fuser unit installation check (Check that the levers fixing the fuser unit are lifted up.) Fuser belt rotation detection sensor • Sensor check (Input check: FS-03-[ALL]OFF/[6]/[A]) • Connector check in the fuser belt rotation sensor (CN306, J604) • Harness check in the fuser belt rotation sensor Fuser drive unit • Bushing check • Check that the drive unit is correctly installed (3 dowels). • Check that the drive metal plate is not broken. • Check that the gear is not damaged or worn. • One-way clutch check • Grease check in the gear (shaft / tooth flank) LGC board • Connector check (CN305, CN306) • Board check. Fuser motor • Motor check (Perform the output check: FS-03-113/163) • Connector check (CN305, J603) • Harness check

Code: C550

Description: RADF I/F error
Causes: RADF board SYS board
Remedy: RADF board • Check if the harness connecting the RADF board and SYS board is disconnected or open circuited. (CN122, J12, CN71) • Check if the conductor pattern on the RADF board is short circuited or open circuited. • Connector check SYS board • Check if the conductor pattern on the SYS board is short circuited or open circuited. • Connector check

Code: C551

Description: RADF model detection error. Incorrect RADF installed to the equipment
Causes: RADF
Remedy: RADF • Replace the RADF with the correct one.

Code: C560

Description: • Communication error between Engine-CPUs • Communication error between LGC-PFU
Causes: LGC board PFC board Harness
Remedy: LGC board • Turn the power OFF and then back ON using the main power switch. • Connector check (CN323) • Check if the conductor pattern on the LGC board is open circuited or short circuited. • Check if the harness between LGC-PFC has any scratch on it or is open circuited or caught anywhere. • If the same error occurs again, replace the LGC board. PFC board • Connector check (CN452) • Check if the conductor pattern on the PFC board is open circuited or short circuited. • Check if the harness between LGC-PFC has any scratch on it or is open circuited or caught anywhere. • If the same error occurs again, replace the PFC board.

Code: C580

Description: Communication error between LGC board and finisher
Causes: Finisher
Remedy: Check if the specified finisher is attached.

Code: C5A0

Description: EEPROM abnormality (LGC board)
Causes: EEPROM LGC board
Remedy: EEPROM EEPROM check LGC board • IC socket check (25/30/35ppm: IC63, 45/50ppm: IC12) • Board check

Code: C5A1

Description: EEPROM data abnormality (LGC board)
Causes: EEPROM LGC board
Remedy: EEPROM EEPROM check LGC board • IC socket check (25/30/35ppm: IC63, 45/50ppm: IC12) • Board check

Code: C8E0

Description: RADF communication protocol abnormality. The system has to be stopped because the control abnormality occurred.
Causes: RADF board
Remedy: Power • Turn the power OFF and then back ON to check if the equipment operates normally. RADF board • Connector check Board check
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie