Description: HDD data error: Abnormality is detected in the data of HDD.
Remedy: (1) Check if the connectors of the HDD are disconnected. (2) Check if the connector pins are disconnected or the wires of harnesses are broken. (3) Perform the bad sector check (08-694). If the check result is OK, recover the data in the HDD. If the check result is failed, replace the HDD. (4) Replace the SYS board.
Remedy: (1) Check if the connectors of the HDD are disconnected. (2) Check if the connector pins are disconnected or the wires of harnesses are broken. (3) Perform the bad sector check (08-694). If the check result is OK, recover the data in the HDD. If the check result is failed, replace the HDD. (4) Replace the SYS board.
Remedy: (1) Turn the power OFF and start up the Setting Mode (08). (2) Key in “662” and press the [START] button. (Partition clearing is performed.) (3) Restart the equipment. (4) Access TopAccess. Click the [Administration] tab, and then click the Maintenance Menu to open. Then install the “Point and Print” driver.
Description: Communication error between System-CPU and Scanner-CPU
Remedy: (1) Check if the jumper pin setting on the SYS board is correct. (Check if a jumper pin is inserted between Pin 1 and Pin 2 of the CN 103 and the CN115.) (2) Check if the harness connecting the SYS board and SLG board is disconnected or open circuited. (3) Check the version of the system ROM on the SYS board. (4) Check the version of the scanner ROM version on the SLG board. (5) Replace the SYS board. (6) Replace the SLG board.
Remedy: (1) Check if the jumper pin setting on the SYS board is correct. (Check if a jumper pin is inserted between Pin 1 and Pin 2 of the CN 103 and the CN115.) (2) Check if the harness connecting the SYS board and SLG board is disconnected or open circuited. (3) Check the version of the system ROM on the SYS board. (4) Check the version of the scanner ROM version on the SLG board. (5) Replace the SYS board. (6) Replace the SLG board.