Description: LCF transport motor abnormality: The LCF transport motor is not rotating normally.
Remedy: Is the LCF transport motor working? (Perform the output check in the test mode: 03-122/ 172) NO 1. Check if the connector of the LCF transport motor is disconnected. 2. Check if the connector CN1, CN3 on the LCF board is disconnected. 3. Check if the connector CN318 on the LGC board is disconnected. 4. Check if the connector pins are disconnected and the harnesses are open circuited. 5. Check if the conductor patterns on the LCF transport motor board, LCF board and LGC board are short circuited or open circuited. 6. Replace the LCF transport motor. 7. Replace the LCF board. 8. Replace the LGC board. YES 1. Check if the connector pins are disconnected and the harnesses are open circuited. 2. Check if the conductor patterns on the LCF transport motor board, LCF board and LGC board are short circuited or open circuited. 3. Check if the PLL lock signal CN3-10 output from the LCF board is always “L” level. 4. Check if the voltage supplied to the microcomputer input terminal IC103-17 is always “L” level. 5. Replace the LCF transport motor. 6. Replace the LCF board. 7. Replace the LGC board.
Code: C260
Description: Peak detection error: Lighting of the exposure lamp (white reference) is not detected when power is turned ON.
Remedy: Does the exposure lamp light? (Perform the output check in the test mode: 03-267) YES 1. Check if the connectors on the CCD and SLG boards are disconnected. 2. Check if the shading correction plate is dirty. 3. Check if the conductor pattern on the CCD board is short circuited or open circuited. 4. Check if the conductor pattern on the SLG board is short circuited or open circuited. 5. Replace the lens unit. 6. Replace the SLG board. NO 1. Check if the connectors of the exposure lamp and inverter are disconnected. 2. Check the SLG board if the connector pin CN12 is disconnected and the harness is short circuited or open circuited. 3. Check if the conductor pattern on the SLG board is short circuited or open circuited. 4. Replace the SLG board. 5. Replace the inverter. 6. Replace the exposure lamp.
Code: C270
Description: Carriage home position sensor not turning OFF within a specified period of time: The carriage does not shift from its home position in a specified period of time.
Remedy: Are the carriages slightly moved to the feeding direction? Are the carriages staying at a position other than home position? YES 1. Check if the connector of the scan motor is disconnected. 2. Check if the connector pin is disconnected and the harness is short circuited or open circuited. 3. Replace the SLG board. NO 1. Check if the connector pin is disconnected and the harness is short circuited or open circuited. 2. Check if the conductor pattern on the SLG board is short circuited or open circuited. 3. Replace the SLG board.
Code: C280
Description: Carriage home position sensor not turning ON within a specified period of time: The carriage does not reach to its home position in a specified period of time.
Remedy: Do the carriages make a big noise after they arrive at the home position? YES The carriage home position sensor is not turned ON. 1. Check if the connector of the sensor is disconnected. 2. Replace the carriage home position sensor. 3. Replace the SLG board. NO The carriages are stopped at the home position and do not move. 1. Check if the connector pins are disconnected and the harnesses are short circuited or open circuited. 2. Check if the conductor pattern on the SLG board is short circuited or open circuited. 3. Replace the SLG board.
Code: C3D0
Description: EPU board memory overwriting error: The overwriting of the EPU board memory fails.
Remedy: (1) Check if the process unit is properly installed, and check if the connector pins that are connected to the equipment are disconnected or have any abnormality such as deformation. (2) Check if the harness connected to the connector J451 on the EPU board has any abnormality. (3) Replace the EPU memory board. (4) Replace the LGC board.
Code: C3D1
Description: EPU board memory new parts detection error: The EPU board detects the process unit as a new unit when the equipment is started in the normal mode.
Remedy: (1) If the process unit has been replaced with a new one before the equipment is started, turn the power OFF and then back ON in the EPU replacement mode ([7] + [START]). (2) If the process unit has not been replaced, check the following. (3) Check if the process unit is properly installed, and check if the connector pins that are connected to the equipment are disconnected or have any abnormality such as deformation. (4) Check if the harness connected to the connector J451 on the EPU board has any abnormality. (5) Replace the EPU memory board. (6) Replace the LGC board.
Code: C3D2
Description: EPU board memory old parts detection error: The EPU board cannot detect the new process unit when the equipment is started in the EPU replacement mode ([7] + [START]).
Remedy: (1) Check if the process unit is a new one. If it is a new one, check the following: (2) Check if the process unit is properly installed, and check if the connector pins that are connected to the equipment are disconnected or have any abnormality such as deformation. (3) Check if the harness connected to the connector J451 on the EPU board has any abnormality. (4) Replace the EPU memory board. (5) Replace the LGC board.
Code: C410
Description: Thermistor or heater abnormality at power-ON: Abnormality of service call the thermistor is detected when power is turned ON or the temperature of the fuser roller does not rise in a specified period of time after power is turned ON.
Remedy: (1) Check if the connectors are disconnected. (2) Check if the center, side and edge thermistors are in contact with the surface of the fuser roller properly? (3) Check if the harnesses of the center, side and edge thermistors are open circuited. 2. Check the heater (1) Check if the heater is broken. (2) Check if the connector of the heater is disconnected. (3) Check if the thermostat is blown. 3. Check the LGC board (1) Check if the connectors CN308 are disconnected. (2) Check if the conductor pattern on the LGC board is short circuited or open circuited. (3) Replace the LGC board. 4. Clear the status counter After repairing the matter which caused the error [C410], perform the following: (1) Turn ON the power while [0] and [8] are pressed simultaneously. (2) Key in “400”, then press [START]. (3) Change the current status counter value “1” or “2” to “0”, then press [ENTER] or [INTERRUPT] (to cancel [C410]). (4) Turn the power OFF and then back ON. Make sure that the equipment enters the normal ready state.