Code: SC632

Description: Key/card counter device error 1. After 1 data frame is sent to the device, an ACK signal is not received within 100 ms, and is not received after 3 retries.
Remedy: • The serial line from the device to the copier is unstable, disconnected, or defective.

Code: SC633

Description: Key/card counter device error 2. During communication with the device, the BICU received a break (Low) signal.
Remedy: • The serial line from the device to the copier is unstable, disconnected, or defective.

Code: SC634

Description: Key/card counter device error 3. After installation of the device, a message alerts user to a backup RAM error.
Remedy: • Device control board defective • Device control board backup battery defective

Code: SC635

Description: Key/card counter device error 4. After installation of the device a message alerts user to a battery voltage abnormal error.
Remedy: • Device control board defective • Device control board backup battery defective

Code: SC670

Description: Engine startup error. • Engine does not respond within 30 s after power ON. • Engine down detected suddenly during power ON and warmup.
Remedy: • BICU installation incorrect • BICU defective • Sudden communication reset occurred between the BICU and the controller.

Code: SC672

Description: GW controller startup error. • After power ON, the line between the GW controller and the operation panel did not open for normal operation. • After normal startup, communication with the GW controller stopped.
Remedy: • GW Controller stalled • GW Controller installed incorrectly • GW Controller board defective • Operation panel harness disconnected or defective

Code: SC680

Description: BICU-MUSIC communication error. The main CPU fails to communicate with the MUSIC CPU within 5 sec. and three attempts failed.
Remedy: • Toner cartridge ID chip harness disconnected, defective • Toner cartridge ID chip defective • Toner cartridge installed incorrectly • Toner cartridge defective • UART communication failure; replace the BICU

Code: SC687

Description: Memory address command error. The BICU does not receive a memory address command from the controller 120 seconds after paper is in the position for registration.
Remedy: • BICU-Controller connection loose, defective • BICU defective • Controller defective
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie