Các lỗi thường gặp

Code :
  • Code: 922.04
  • Description: Hot roll timed out in trying to reach the final lamp detection temperature. Fuser page count between 0 and 99,999.
  • Causes: • Low wattage or incorrect lamp. • Bad thermistor, circuit, or cabling. • Fuser not receiving sufficient AC power. • Poor supply line voltage.
  • Remedy: See 922.02
  • Code: 922.06
  • Description: Hot roll did not reach operating temperature in time (new enhanced control). Fuser page count between 0 and 99,999.
  • Causes: • Low wattage or incorrect lamp. • Bad thermistor, circuit, or cabling. • Fuser not receiving sufficient AC power. • Poor supply line voltage.
  • Remedy: See 922.02
  • Code: 922.07
  • Description: Fuser has taken too long to reach desired temperature after increasing interrupt gap. Fuser page count between 0 and 99,999.
  • Causes: • Low wattage or incorrect lamp. • Bad thermistor, circuit, or cabling. • Fuser not receiving sufficient AC power. • Poor supply line voltage.
  • Remedy: See 922.02
  • Code: 922.12
  • Description: Hot roll took too long to reach the beginning lamp detection temperature. Fuser page count between 100,000 and 199,999.
  • Causes: • Low wattage or incorrect lamp. • Bad thermistor, circuit, or cabling. • Fuser not receiving sufficient AC power. • Poor supply line voltage.
  • Remedy: See 922.02
  • Code: 922.13
  • Description: Hot roll reached final lamp detection temperature but took longer than largest time in lookup table. Fuser page count between 100,000 and 199,999.
  • Causes: • Low wattage or incorrect lamp. • Bad thermistor, circuit, or cabling. • Fuser not receiving sufficient AC power. • Poor supply line voltage.
  • Remedy: See 922.02
  • Code: 922.14
  • Description: Hot roll timed out in trying to reach the final lamp detection temperature. Fuser page count between 100,000 and 199,999.
  • Causes: • Low wattage or incorrect lamp. • Bad thermistor, circuit, or cabling. • Fuser not receiving sufficient AC power. • Poor supply line voltage.
  • Remedy: See 922.02
  • Code: 922.15
  • Description: After hot roll lamp detection, did not roll over to steady state control in time. Fuser page count between 100,000 and 199,999.
  • Causes: The control code has been lost.
  • Remedy: See 922.02
  • Code: 922.16
  • Description: Hot roll did not reach operating temperature in time (new enhanced control). Fuser page count between 100,000 and 199,999.
  • Causes: • Low wattage or incorrect lamp. • Bad thermistor, circuit, or cabling. • Fuser not receiving sufficient AC power. • Poor supply line voltage.
  • Remedy: See 922.02