Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Toshiba e-Studio 4511 — Trang 22/22

Code: F110

Description: Communication error between System-CPU and Scanner- CPU
Remedy: (1) Check if the harness connecting the SYS board and SLG board is disconnected or open-circuited. (2) Check the version of the system ROM on the SYS board. (3) Check the version of the scanner ROM version on the SLG board. (4) Replace the SYS board. (5) Replace the SLG board.

Code: F111

Description: Scanner response abnormality
Remedy: (1) Check if the harness connecting the SYS board and SLG board is disconnected or open-circuited. (2) Check the version of the system ROM on the SYS board. (3) Check the version of the scanner ROM version on the SLG board. (4) Replace the SYS board. (5) Replace the SLG board.

Code: F120

Description: Database abnormality: Database is not operating normally.
Remedy: (1) Rebuild the databases. (Perform 08-684.) (2) If the error is not recovered, initialize the HDD. (Enter “2” at 08-690.) * When “Rebuilding all databases (08-684)” is performed, all data in the Address Book and Mailbox are deleted. Make sure to back up these data in advance of rebuilding and restore the data after rebuilding.

Code: F350

Description: SLG board abnormality
Remedy: (1) Check if the conductor pattern on the SLG board is short- or open-circuited. (2) Replace the SLG board.