Code: C3A1

Description: Auto-toner sensor-M abnormality (lower limit)
Causes: Auto-toner sensor-K/-C/-M/-Y Developer unit mixer motor-K/YMC EPU board LGC board
Remedy: Developer unit mixer motor-K/YMC • Motor check (Perform the output check: K: 03-114 TMC: 03-115) EPU tray (process unit) • Connection check (05-2788) • Connector check • Harness check EPU board • Connector check (CN550, CN551, CN553,CN554, CN555, CN556) • Board check LGC board • Connector check (CN308, CN310) • Board check

Code: C3A2

Description: Auto-toner sensor-M connection error
Causes: Auto-toner sensor-K/-C/-M/-Y Developer unit mixer motor-K/YMC EPU board LGC board
Remedy: Developer unit mixer motor-K/YMC • Motor check (Perform the output check: K: 03-114 TMC: 03-115) EPU tray (process unit) • Connection check (05-2788) • Connector check • Harness check EPU board • Connector check (CN550, CN551, CN553,CN554, CN555, CN556) • Board check LGC board • Connector check (CN308, CN310) • Board check

Code: C3B0

Description: Auto-toner sensor-Y abnormality (upper limit)
Causes: Auto-toner sensor-K/-C/-M/-Y Developer unit mixer motor-K/YMC EPU board LGC board
Remedy: Developer unit mixer motor-K/YMC • Motor check (Perform the output check: K: 03-114 TMC: 03-115) EPU tray (process unit) • Connection check (05-2788) • Connector check • Harness check EPU board • Connector check (CN550, CN551, CN553,CN554, CN555, CN556) • Board check LGC board • Connector check (CN308, CN310) • Board check

Code: C3B1

Description: Auto-toner sensor-Y abnormality (lower limit)
Causes: Auto-toner sensor-K/-C/-M/-Y Developer unit mixer motor-K/YMC EPU board LGC board
Remedy: Developer unit mixer motor-K/YMC • Motor check (Perform the output check: K: 03-114 TMC: 03-115) EPU tray (process unit) • Connection check (05-2788) • Connector check • Harness check EPU board • Connector check (CN550, CN551, CN553,CN554, CN555, CN556) • Board check LGC board • Connector check (CN308, CN310) • Board check

Code: C3B2

Description: Auto-toner sensor-Y connection error
Causes: Auto-toner sensor-K/-C/-M/-Y Developer unit mixer motor-K/YMC EPU board LGC board
Remedy: Developer unit mixer motor-K/YMC • Motor check (Perform the output check: K: 03-114 TMC: 03-115) EPU tray (process unit) • Connection check (05-2788) • Connector check • Harness check EPU board • Connector check (CN550, CN551, CN553,CN554, CN555, CN556) • Board check LGC board • Connector check (CN308, CN310) • Board check

Code: C3C0

Description: Process unit connection error
Causes: EPU board LGC board
Remedy: EPU tray (process unit) • Connection check (05-2788) • Connector check • Harness check EPU board • Connector check (CN551) • Board check LGC board • Connector check (CN308) • Board check

Code: C411

Description: Thermistor or IH abnormality at power-ON
Causes: Thermopiles Fuser unit IH coil IH board LGC board
Remedy: Power voltage • Check if the power voltage is normal.(Is the voltage during the operation ±10% of the rated voltage?) Error detection history Check the error detection history of each temperature detecting element when the error occurred. If any of the elements detects an abnormal temperature, check step 3. • 08-4530: Fuser belt center thermopile temperature • 08-4532: Fuser belt edge thermistor temperature • 08-4533: Pressure roller center thermistor temperature • 08-4545: Pressure roller rear thermistor temperature Thermopiles • Check if the fuser belt center and side thermopiles (front, rear) are installed properly. • Check if the harnesses of the fuser belt center and side thermopiles (front, rear) are open circuited. Fuser unit • Unit check • Connector check • Harness check IH coil • Connector check • Harness check IH board • Connector check • Harness check LGC board • Connector check (CN305, CN306) • Harness check Status counter 1. [0], [8] Power ON. 2. Key in “2002”, then press [START]. 3. Change the current status counter value “1” or “2” to “0”, then press [ENTER] or [INTERRUPT] (to cancel [C411/ C412]).) 4. Turn the power OFF and then back ON. Make sure that the equipment enters the normal ready state.

Code: C412

Description: Thermistor/IH abnormality at power-ON
Causes: Thermopiles Fuser unit IH coil IH board LGC board
Remedy: Power voltage • Check if the power voltage is normal.(Is the voltage during the operation ±10% of the rated voltage?) Error detection history Check the error detection history of each temperature detecting element when the error occurred. If any of the elements detects an abnormal temperature, check step 3. • 08-4530: Fuser belt center thermopile temperature • 08-4532: Fuser belt edge thermistor temperature • 08-4533: Pressure roller center thermistor temperature • 08-4545: Pressure roller rear thermistor temperature Thermopiles • Check if the fuser belt center and side thermopiles (front, rear) are installed properly. • Check if the harnesses of the fuser belt center and side thermopiles (front, rear) are open circuited. Fuser unit • Unit check • Connector check • Harness check IH coil • Connector check • Harness check IH board • Connector check • Harness check LGC board • Connector check (CN305, CN306) • Harness check Status counter 1. [0], [8] Power ON. 2. Key in “2002”, then press [START]. 3. Change the current status counter value “1” or “2” to “0”, then press [ENTER] or [INTERRUPT] (to cancel [C411/ C412]).) 4. Turn the power OFF and then back ON. Make sure that the equipment enters the normal ready state.
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie