Description: Key consistency error: Signature Check public key damage.
Causes:
Remedy: Reboot the equipment. If it cannot be recovered, reinstall the software in the following procedure. (1) Install the OS data. (2) Reinstall the master data and application program.
Description: Communication error between System-CPU and Scanner-CPU
Causes: SYS board SLG board
Remedy: Reproducibility Turn the power OFF and then back ON using the main power switch. SYS board • Check the version of the system ROM. • Connector check SLG board • Check the version of the scanner ROM. • Connector check IMG board • Connector check
Remedy: Reproducibility Turn the power OFF and then back ON using the main power switch. SYS board • Check the version of the system ROM. • Connector check SLG board • Check the version of the scanner ROM. • Connector check IMG board • Connector check
Description: Database abnormality: Database is not operating normally
Causes:
Remedy: Setting 1. Check that no jobs remain and rebuild the databases. ([5] + [C] + [POWER] → 4. Initialize database → 1. LDAP DB and 2. Log DB (Job,Msg). 2. If the error is not recovered, reinstall the system software. ([4] + [9] + [POWER] → 4. System Software(HD data)) Notes: • If you rebuild the databases with a job remaining, delete it after finishing. • When "Rebuilding all databases” is performed, all data including log/user/role/group/department information and address book data are deleted. If you back up the data in advance, they will be recovered by restoring them after rebuilding the database.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.