Remedy: Setting Reset the date, and request the administrator to set the date and time. 1. Turn the power on while pressing the [6] and [CLEAR] button. 2. Select [2] key, and then press the [START] button. 3. Press the [START] button on the confirmation screen displayed. (The date is set to January 1st, 2011.) 4. Request the administrator to set the date and time.
Code: F900
Description: Model information error
Causes:
Remedy: Setting Recover the machine information by means of the following procedure. Notes: The following procedure is supported in the firmware with the version “2050” or later. If the version is before “2050”, first upgrade it to “2050” or later with [4] + [9] → [1] for “SYSTEM FIRMWARE (OS Data)”. <Machine information recovery> 1. Turn the power ON while pressing [6] and the [CLEAR] button simultaneously. 2. Key in [3] to select “3. SRAM Re-Initialize Support”, and then press the [START] button. 3. After the operation is completed, shut down the equipment by pressing the [ON/OFF] button. * If it is not recovered, perform the following procedure. 4. Turn the power ON while pressing [3] and the [CLEAR] button simultaneously. 5. Enter the password on the Authentication screen. If no password is set for Service, press the [OK] button without entering anything. If the High Security Mode has been set, enter “#1048#”. 6. Key in [5] to select “5. Key Backup Restore”, and then press the [START] button. 7. Key in [2] to select “2. Key FROM to SRAM”, and then press the [START] button. 8. After the operation is completed, shut down the equipment by pressing the [ON/OFF] button.