Code: CA4

Description: Primary scanning counter load error
Remedy: Are the harness(es) between the PLG board and the galvanomirror, PLG board and laser drive board, and PLG board and HSYNC board broken, and connector(s) disconnected? Yes Replace the harness(es), and re-connect the connector(s). No • Replace the PLG board. • Replace the unit.

Code: CA5

Description: Laser power adjustment error
Remedy: Are the harness(es) between the PLG board and the galvanomirror, PLG board and laser drive board, and PLG board and HSYNC board broken, and connector(s) disconnected? Yes Replace the harness(es), and re-connect the connector(s). No • Replace the PLG board. • Replace the unit.

Code: CA6

Description: Laser PWM calibration error
Remedy: Are the harness(es) between the PLG board and the galvanomirror, PLG board and laser drive board, and PLG board and HSYNC board broken, and connector(s) disconnected? Yes Replace the harness(es), and re-connect the connector(s). No • Replace the PLG board. • Replace the unit.

Code: CA9

Description: Image data transmission error from SYS board
Remedy: Is the harness between the PLG board and the SYS board broken, and connector disconnected? Yes Replace the harness, and re-connect the connector. No • Replace the PLG board. • Replace the SYS board.

Code: CAA

Description: Secondary scanning fine adjustment error
Remedy: Are the harness(es) between the PLG board and the galvanomirror, PLG board and laser drive board, and PLG board and HSYNC board broken, and connector(s) disconnected? Yes Replace the harness(es), and re-connect the connector(s). No • Replace the PLG board. • Replace the unit.

Code: CAB

Description: Secondary scanning inter-page compensation error
Remedy: Are the harness(es) between the PLG board and the galvanomirror, PLG board and laser drive board, and PLG board and HSYNC board broken, and connector(s) disconnected? Yes Replace the harness(es), and re-connect the connector(s). No • Replace the PLG board. • Replace the unit.

Code: CAC

Description: Primary scanning dot adjustment error
Remedy: Are the harness(es) between the PLG board and the galvanomirror, PLG board and laser drive board, and PLG board and HSYNC board broken, and connector(s) disconnected? Yes Replace the harness(es), and re-connect the connector(s). No • Replace the PLG board. • Replace the unit.

Code: CAD

Description: Primary scanning tap adjustment error
Remedy: Are the harness(es) between the PLG board and the galvanomirror, PLG board and laser drive board, and PLG board and HSYNC board broken, and connector(s) disconnected? Yes Replace the harness(es), and re-connect the connector(s). No • Replace the PLG board. • Replace the unit.